background image

 

Page 16 of 16 

2453-222/2453-422/2453-522 - Rev: 1/21/2014 7:51 AM  

Limitations 

The above warranty is in lieu of and Seller disclaims all other warranties, whether oral or written, express or implied, including any warranty or merchantability or fitness 
for a particular purpose. Any implied warranty, including any warranty of merchantability or fitness for a particular purpose, which may not be disclaimed or supplanted 
as provided above shall be limited to the two-year of the express warranty above. No other representation or claim of any nature by any person shall be binding upon 
Seller or modify the terms of the above warranty and disclaimer.  
Home automation devices have the risk of failure to operate, incorrect operation, or electrical or mechanical tampering. For optimal use, manually verify the device 
state. Any home automation device should be viewed as a convenience, but not as a sole method for controlling your home.  

In no event shall Seller be liable for special, incidental, consequential, or other damages resulting from possession or use of this device, including without limitation 
damage to property and, to the extent permitted by law, personal injury, even if Seller knew or should have known of the possibility of such damages. Some states do 
not allow limitations on how long an implied warranty lasts and/or the exclusion or limitation of damages, in which case the above limitations and/or exclusions may not 
apply to you. You may also have other legal rights that may vary from state to state.  

U.S Patent No. 7,345,998, International patents pending 
© Copyright 2011 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 866-243-8022

www.insteon.com

 

Summary of Contents for 2453-222

Page 1: ...Page 1 of 16 2453 222 2453 422 2453 522 Rev 1 21 2014 7 51 AM DIN Rail On Off Owner s Manual 2453 222 US 2453 422 EU 2453 522 AUS NZ...

Page 2: ...s 6 Change LED Brightness 6 Error Blink 7 INSTEON Setup 7 INSTEON Controllers Responders and Links 7 Make DIN Rail a Responder 7 Make DIN Rail a Controller 7 Groups 8 Scenes 8 Make DIN Rail a Controll...

Page 3: ...pecified maximum s or install in locations with electricity specifications which are outside of the product s specifications If this device supports dimming please note that dimming an inductive load...

Page 4: ...off breaker fuse and verify power is off 2 Disconnect wires from light fixture Strip away wire coating until you have 5 16 8mm of bare wire on the ends 3 After ensuring the wires are not touching tur...

Page 5: ...y 3 Way Toggle Mode Latching Switches Only Default Because DIN Rail module comes programmed for latching switches 3 way toggle mode is enabled by default Normally a latching switch reads the switch s...

Page 6: ...Single Momentary Wall Switch Dual Momentary Wall Switch Adjust Local Settings Change LED Brightness DIN Rail s LED is set at a default 50 brightness but it can be set anywhere from off to 100 brightn...

Page 7: ...nders only e g FanLinc and some can be controllers and responders e g switches and dimmers The association between the controller and responder is called a link Note that a link is one way If you want...

Page 8: ...ng device A is now a controller of device B 4 Press and hold device B set button until it beeps Device B LED will start blinking green 5 Press and hold device A set button until it double beeps Device...

Page 9: ...on until it beeps Controller LED will start blinking green 2 Press and hold controller button until it beeps a second time Controller LED will start blinking red 3 Press and hold DIN Rail set button u...

Page 10: ...beep and its LED will stop blinking 3 Test by sending X10 on and off commands Load will turn on and off Remove X10 Address 1 Press and hold DIN Rail set button until it beeps DIN Rail LED will start b...

Page 11: ...ct beacon Yes INSTEON device category 0x02 Switched Lighting Control all frequencies INSTEON device subcategory US 0x2E EU 0x33 AUS NZ 0x34 X10 X10 address 1 optional comes unassigned X10 transmitter...

Page 12: ...mum load None User replaceable fuse US 16A 5x20mm slow blow burn glass fuse EU No user replaceable fuse AUS NZ Hardwired remote control Yes either latching or momentary switches supported Retains all...

Page 13: ...ot using DIN Rail in X10 mode DIN Rail may have an undesired responder membership Use software to remove membership or perform a factory reset DIN Rail responds to on commands but not off commands Loa...

Page 14: ...ice provides a phase bridge to DIN Rail module If the other dual band device is blinking red it is on the same phase Device does not provide a phase bridge to DIN Rail module Relocate if necessary and...

Page 15: ...ires that the equipment bearing this symbol on the product and or its packaging must not be disposed of with unsorted municipal waste The symbol indicates that this product should be disposed of separ...

Page 16: ...or electrical or mechanical tampering For optimal use manually verify the device state Any home automation device should be viewed as a convenience but not as a sole method for controlling your home...

Reviews: