Load brightness levels 

32 locally (256 with software) 

LED 

Green when load is on, red when load is off. 
Blinks red when responder does not acknowledge (can be disabled via 
software).  
Blinks red or green during setup. 

LED brightness 

Adjustable, from off to bright 

Local control 

Yes 

Commands supported as controller 

On/off, Fast on/off, Begin brighten/dim, End brighten/dim 

Commands supported as responder 

On/off, Fast on/off, Beep 

Software configurable 

Yes 

RF range 

Up to 150 feet (50 meters) open air* 

*Range may vary due to local interference 

Phase detect beacon 

Yes 

INSTEON device category 

0x02 Switched Lighting Control (all frequencies)  

INSTEON device subcategory 

US 

0x2E 

EU 

0x33 

AUS/NZ 

0x34 

X10 

X10 address 

1 optional (comes unassigned) 

X10 transmitter 

Yes 

X10 receiver 

Yes 

X10 status response 

Supported 

X10 resume dim 

Supported (by setting local on-level to zero) 

X10 minimum transmit level 

3.2 Vpp into 5 Ohms 

X10 minimum receive level 

20mV into 5 Ohms 

X10 messages repeated 

No 

Mechanical 

Mounting 

35mm (top hat) DIN Rail 

Wires 

NA 

Max Cable Size 

4mm2, 12 AWG (2.72mm Diameter) 

Min Cable Size 

1.5mm2, 15 AWG 

Screw DIN Rail connections 

Line, Neutral, Load, Sense 1, Sense 2 

Case color  

White 

Set button 

Yes 

Plastic 

UV stabilized polycarbonate 

Beeper 

Yes 

Beep on button press 

Optional (off by default) 

LED 

1, RGB 

Dimensions 

3.14"H x 2.05"W x 2.48"D (80mm x 52mm x 63mm) 

Summary of Contents for 2453-222

Page 1: ...Page 1 of 16 2453 222 2453 422 2453 522 Rev 1 21 2014 7 51 AM DIN Rail On Off Owner s Manual 2453 222 US 2453 422 EU 2453 522 AUS NZ...

Page 2: ...s 6 Change LED Brightness 6 Error Blink 7 INSTEON Setup 7 INSTEON Controllers Responders and Links 7 Make DIN Rail a Responder 7 Make DIN Rail a Controller 7 Groups 8 Scenes 8 Make DIN Rail a Controll...

Page 3: ...pecified maximum s or install in locations with electricity specifications which are outside of the product s specifications If this device supports dimming please note that dimming an inductive load...

Page 4: ...off breaker fuse and verify power is off 2 Disconnect wires from light fixture Strip away wire coating until you have 5 16 8mm of bare wire on the ends 3 After ensuring the wires are not touching tur...

Page 5: ...y 3 Way Toggle Mode Latching Switches Only Default Because DIN Rail module comes programmed for latching switches 3 way toggle mode is enabled by default Normally a latching switch reads the switch s...

Page 6: ...Single Momentary Wall Switch Dual Momentary Wall Switch Adjust Local Settings Change LED Brightness DIN Rail s LED is set at a default 50 brightness but it can be set anywhere from off to 100 brightn...

Page 7: ...nders only e g FanLinc and some can be controllers and responders e g switches and dimmers The association between the controller and responder is called a link Note that a link is one way If you want...

Page 8: ...ng device A is now a controller of device B 4 Press and hold device B set button until it beeps Device B LED will start blinking green 5 Press and hold device A set button until it double beeps Device...

Page 9: ...on until it beeps Controller LED will start blinking green 2 Press and hold controller button until it beeps a second time Controller LED will start blinking red 3 Press and hold DIN Rail set button u...

Page 10: ...beep and its LED will stop blinking 3 Test by sending X10 on and off commands Load will turn on and off Remove X10 Address 1 Press and hold DIN Rail set button until it beeps DIN Rail LED will start b...

Page 11: ...ct beacon Yes INSTEON device category 0x02 Switched Lighting Control all frequencies INSTEON device subcategory US 0x2E EU 0x33 AUS NZ 0x34 X10 X10 address 1 optional comes unassigned X10 transmitter...

Page 12: ...mum load None User replaceable fuse US 16A 5x20mm slow blow burn glass fuse EU No user replaceable fuse AUS NZ Hardwired remote control Yes either latching or momentary switches supported Retains all...

Page 13: ...ot using DIN Rail in X10 mode DIN Rail may have an undesired responder membership Use software to remove membership or perform a factory reset DIN Rail responds to on commands but not off commands Loa...

Page 14: ...ice provides a phase bridge to DIN Rail module If the other dual band device is blinking red it is on the same phase Device does not provide a phase bridge to DIN Rail module Relocate if necessary and...

Page 15: ...ires that the equipment bearing this symbol on the product and or its packaging must not be disposed of with unsorted municipal waste The symbol indicates that this product should be disposed of separ...

Page 16: ...or electrical or mechanical tampering For optimal use manually verify the device state Any home automation device should be viewed as a convenience but not as a sole method for controlling your home...

Reviews: