![Instantel 716A0401 Operator'S Manual Download Page 45](http://html1.mh-extra.com/html/instantel/716a0401/716a0401_operators-manual_2069776045.webp)
Compliance Module
MiniMate Plus Operator Manual
3–25
the
Right Arrow
key to move the cursor and the
Up Arrow
key to change the time setting. Press
the
Enter
key to save your setting.
g. Monitoring LCD Cycle
The Monitoring LCD Cycle is a timer that automatically starts a power saving mode. While in this
mode, the MiniMate Plus minimizes power consumption while continuing its monitoring
operations. The monitor display cycles off for the time period set in this command, turns on the
display momentarily, then cycles again. To turn this feature off, set the time to zero. To reactivate
the monitor and see the display, press the
Enter
key.
To set the monitoring LCD cycle, press the
Option
key and the
Setups
key together when the
Main Window is displayed. Press the
Cancel
key to exit the Reset Factory Defaults Window.
Press the
Enter
key to scroll through the windows until the Monitoring LCD Cycle Window
appears. Use the
Right Arrow
key to move the cursor and the
Up Arrow
key to change the time
setting. Press the
Enter
key to save your setting.
h. Trigger Sample Width
You can specify the number of consecutive samples that must exceed the trigger level before the
unit will start recording. The default is 2 samples.
To set the trigger sample width, press the
Option
key and the
Setups
key together when the Main
Window is displayed. Press the
Cancel
key to exit the Reset Factory Defaults Window. Press the
Enter
key to scroll through the windows until the Trigger sample width Window appears. Use the
Up Arrow
key to change the setting. Press the
Enter
key to save your setting.
i. Cut Cable Detection
This setting is used to automatically disable a geophone channel as a trigger if the cable is cut or
damaged. While in continuous mode, the unit checks each geophone channel after an event is
recorded. If there is a problem, the unit automatically disables that channel as a trigger source for
subsequent events. This feature does not apply to the single-shot, manual, histogram or histogram
combo modes.
To enable cut cable detection, press the
Option
key and the
Setups
key together when the Main
Window is displayed. Press the
Cancel
key to exit the Reset Factory Defaults Window. Press the
Enter
key to scroll through the windows until the Cut Cable Detection Window appears. Use the
Up Arrow
key to change the setting. Press the
Enter
key to save your setting.
3.13.2. Option Key + Test Key = Review Setups
Press these two keys together to review the MiniMate Plus setups. Reviewing the MiniMate Plus
setups scrolls you through the current settings allowing you to check the setups without having to
enter each setting’s individual window.
3.13.3. Option Key + Enter Key = On–Line Help
Press these two keys at the same time to see help information on the monitor’s display.
3.13.4. Option Key + Cancel Key = Backlight ON
Pressing the
Option
key and the
Cancel
key together turns on the backlight and illuminates the
display.
3.13.5. Option Key + Up Arrow Key = Down Arrow
Pressing these two keys together acts as a down arrow.
Summary of Contents for 716A0401
Page 1: ......
Page 6: ...iv MiniMate Plus Operator Manual Notes...
Page 12: ...x MiniMate Plus Operator Manual Notes...
Page 16: ...Chapter 1 1 4 MiniMate Plus Operator Manual 1 4 MiniMate Plus Keys...
Page 66: ...Chapter 5 5 16 MiniMate Plus Operator Manual Notes...
Page 71: ...Appendix MiniMate Plus Operator Manual A 1 Appendix...
Page 72: ...Appendix A 2 MiniMate Plus Operator Manual...
Page 81: ...Appendix MiniMate Plus Operator Manual A 11 Notes...