Chapter 3
3–24
MiniMate Plus Operator Manual
Enter
key to scroll through the windows until the Auto Window appears. Use the
Right Arrow
key to move the cursor and the
Up Arrow
key to change the time setting. Press the
Enter
key to
save your setting.
c. Password
This feature activates a password control requiring an operator to enter a password before being
able to exit the monitor mode. The password prevents an unauthorized exit from monitor mode
while still allowing an operator to view event summaries. Password control can be enabled or
disabled. The default password is four up arrows in a row. Passwords may include any
combination of the Up Arrow key, Right Arrow key, Setups key, Test key, and the Start Monitor
key. Passwords can be enabled in all monitoring modes except the advanced mode.
To display the password feature, press the
Option
key and the
Setups
key together when the main
window is displayed. Press the
Cancel
key to exit the Reset Factory Defaults Window and display
the Password Window. Use the
Up
or
Right Arrow
key to display Enabled to turn the password
on or Disabled to turn the password off. Press the
Enter
key. Enter a password and press the
Enter
key. Enter the password again to confirm your original choice and press the
Enter
key.
d. Auxiliary Trigger
The auxiliary trigger is an external triggering mechanism used to start monitor recording.
A variety of optional auxiliary triggers are available including the DS 20 Wire Trigger
(677A9601), and the BlastMate Trigger Cable (712A3901) used to connect several monitors
together for multiple point blast monitoring.
To use the auxiliary trigger, set the monitor in the single shot or continuous record mode. Set a
fixed record time. The auxiliary trigger does not operate in the auto record time setting. Press the
Option
key and the
Setups
key together when the Main Window is displayed. Press the
Cancel
key to exit the Reset Factory Defaults Window and display the Auto Window. Press the
Enter
key to display the Auxiliary Trigger Window. Use the
Up
or
Right Arrow
key to display Enabled
to turn the auxiliary trigger on or Disabled to turn the auxiliary trigger off. Press the
Enter
key to
save your setting.
e. Backlight On Time
This command sets the length of time the backlight remains on. If enabled, the backlight turns on
by pressing the
Option
key and the
Cancel
key together. An adjustable timer, from 0 to 255
seconds, determines the length of time the backlight remains on. To disable the backlight and not
have it turn on, set the timer delay to 0. This conserves battery power.
To set the backlight timer, press the
Option
key and the
Setups
key together when the Main
Window is displayed. Press the
Cancel
key to exit the Reset Factory Defaults Window. Press the
Enter
key to scroll through the windows until the Backlight On Time Window appears. Use the
Right Arrow
key to move the cursor and the
Up Arrow
key to change the time setting. Press the
Enter
key to save your setting.
f. Power Saving Timeout
The Power Saving Timeout is a timer that automatically turns the MiniMate Plus off when it has
remained in the ready to monitor mode with the Main Window displayed for a specified period of
time. To turn the monitor on again, press and hold the
Enter
key.
To set the power saving timer, press the
Option
key and the
Setups
key together when the Main
Window is displayed. Press the
Cancel
key to exit the Reset Factory Defaults Window. Press the
Enter
key to scroll through the windows until the Power Saving Timeout Window appears. Use
Summary of Contents for 716A0401
Page 1: ......
Page 6: ...iv MiniMate Plus Operator Manual Notes...
Page 12: ...x MiniMate Plus Operator Manual Notes...
Page 16: ...Chapter 1 1 4 MiniMate Plus Operator Manual 1 4 MiniMate Plus Keys...
Page 66: ...Chapter 5 5 16 MiniMate Plus Operator Manual Notes...
Page 71: ...Appendix MiniMate Plus Operator Manual A 1 Appendix...
Page 72: ...Appendix A 2 MiniMate Plus Operator Manual...
Page 81: ...Appendix MiniMate Plus Operator Manual A 11 Notes...