4
The incoming water pressure is too high for the machine to
operate
5
The incoming water pressure is too low for the machine to
operate. The water supply is turned off.
6
The boiler has failed to fill in the allotted time. Possible causes:-
1. The water supply is turned off
2. The inlet valve has failed
3. the water inlet hose is kinked, blocked or detached
7
The element(s) have been on for too long with lower sensor
exposed. Possible leak, lime scale or broken probe wire
8
Pressure switch wire has shorted (wire A)
9
Pressure switch wire has shorted (wire B)
10
The element(s) have been trying to heat the water but have
failed to do so. The element(s) or control system have failed
11
Water supply is turned off and the low probe has become
exposed. Probable lime-scale build up or water supply problem
SERVICE/TECHNICAL SUPPORT:
Tel: 01704 502911
To ensure your service enquiry is handled as efficiently as possible, please have the following
information available;
-
Brief description of problem
-
Product Type (model)
-
Serial Number (label on right-hand side of machine). This is essential