51
Configura
tion
Maximum
Operating
Temperature: 30°C
(86°F)
Maximum
Operating
Temperature: 35°C
(95°F)
Maximum
Operating
Temperatu
re: 40°C
(104°F)
Maximum
Operating
Temperatu
re: 45°C
(113°F)
The maximum operating temperature supported when a single fan fails is 5°C
(9°F) below the normal operating temperature.
Single fan failure may affect system performance.
It is recommended to deploy your servers at an interval of a 1U space to reduce
server noise and improve server energy efficiency.
11.2
Model
Certified Model
Description
NF5448A6
Global
11.3
RAS Features
NF5448A6 supports a variety of RAS (Reliability, Availability, and Serviceability) features.
By configuring these features, NF5448A6 can provide greater reliability, availability, and
serviceability.
11.4
Sensor List
Item
Feature
Description
01
Sys_Inlet_Temp1
System inlet air temperature (located at the
mounting ear)
02
CPU0_Temp
CPU0 temperature
03
CPU1_Temp
CPU1 temperature
04
CPU0_DIMM_Temp
The maximum temperature of the
corresponding DIMMs of CPU0
05
CPU1_DIMM_Temp
The maximum temperature of the
corresponding DIMMs of CPU1
06
CPU0_VR_Temp
CPU0 VR temperature
07
CPU1_VR_Temp
CPU1 VR temperature
08
DIMM0_VR_Temp
The maximum temperature of the
corresponding DIMM VR of CPU0