13
Operations
4 Operations
4.1 Power up the Server
Insert the power cord plug, then press the Power Button.
4.2 Power down the Server
WARNING:
To reduce the risk of personal injury, electric shock, or damage to the equipment,
remove the power cord to remove power from the server. The front panel Power Button
does not completely shut off system power. Portions of the power supply and some internal
circuitry remain active until AC power is removed.
IMPORTANT: I
f installing a hot-plug device, it is not necessary to power down the server.
1.
Back up the server data.
2.
Shut down the operating system.
3.
Disconnect the power cords.
The system is now without power.
4.3 Extend the Server from the Rack
1.
Open the handles outward and use a screwdriver to unlock the screws inside the left and
right ears.
2.
Extend the server from the rack.
3.
Rails are divided into two sections to slide out, that is:
3.1
When the fan needs online-maintenance, only pull out the first part of the rails, about
580mm (22.8 inches), and open the front access panel, to maintain the fan module or
motherboard on the rack.
3.2
When the whole machine needs maintenance, pull out the rails completely, about 100
centimeters (39.4 inches), you need to unlock the buckles on both sides of the rails
so that you can extend the chassis from the rack completely (Note: When the chassis
should be extended completely, make sure that the rear cables have all been removed).
WARNING:
To reduce the risk of personal injury or equipment damage, be sure that the
rack is adequately stabilized before extending a component from the rack.
Summary of Contents for NF5288M5
Page 1: ...Inspur Yitian Supercomputer User Manual NF5288M5 ...
Page 86: ...80 ...
Page 88: ...82 ...
Page 89: ...83 BMC Settings ...
Page 91: ...85 BMC Settings One key collect log One key collect log ...
Page 92: ...86 ...
Page 95: ...89 BMC Settings Restore factory defaults To restore BMC s configuration to factory state ...
Page 96: ...90 ...