14
METRIC-INCH SYSTEM AND INCLINE ADJUSTMENT
•
Push START button. Remove the safety key and insert it again. Now you can switch between
the metric and the inch system. Push SPEED+/- to choose metric (SI) or inch (ENG) system
(on the speed window). After selection push START to confirm it and go to standby state.
•
At the standby state press SPEED+/-, /- keys at the same time for 3 seconds. Enter
the automatic incline adjustment. After adjusting enter the standby state.
ERRORS AND TROUBLESHOOTING
SIGN
DESCRIPTION
PROCESSING
Er-1
No reaction signal of the computer.
•
Check if the computer wire is loose or
fallen out.
•
Check connection between computer
and controller.
Er-2
Incline system failure
•
Check the signal line of the incline
motor.
•
Check if the incline motor is damaged.
•
Check if the controller is damaged.
Er-3
Over-voltage protection
•
Check proper voltage of AC220-240V.
Er-4
Over-current protection
•
Check if the moving parts stuck.
•
Check the lubrication. If the lubrication is
insufficient, add oil.
•
Check if the running board is worn.
•
Check the motor and the controller for
damage.
Er-5
Over-load protection
•
Check if the moving parts stuck.
•
Check the lubrication. If the lubrication is
insufficient, add oil.
•
Check if the running board is worn.
•
Check the motor and the controller for
damage.
Er-6
Motor is not well connected.
•
Check the correct motor connection.
•
Check the motor or controller for
damage.
Er-7
Failure of the controller detect signal.
•
Check connection of the computer wire.
•
Check connection between computer
and controller.
SAFE
Safe lock fault.
•
Check if the safe lock is in right place.
•
Check the magnetic plug.
Display doesn’t work.
•
Check the power outlet.
•
Check if the power switch is on.
•
Check the socket and fuses.