background image

7

 ① 

Measure mode

 Under the menu of measure mode, there are three kinds of mode: 

Average value mode, maximum value mode and maximum 
average value mode.

 Average value mode: During one sampling process, the durometer

will record 20 values and calculate the average value of this 20 
value automatically.
The average value will show on the screen. Under this mode, the 
statistic times can be set. After one measure process is finished, 
the durometer will calculate the average value and peak difference 
of the data until now automatically. If the statistic time is meet, the 
last average value will be saved as the measure result.

 Maximum value mode: During one sampling process, the 

durometer will record 20 values automatically and take the 
maximum value as the current result. Under this mode, the  

Maximum average value mode: During one sampling process, 
the durometer will record 20 values automatically and take the 
maximum value as the current result. Under this mode, the statistic 
times setting can be set. After one measure process is finished,  
the durometer will calculate the average value and peak difference  
of the data until now automatically. The average value of maximum 
value of every measuring will be calculated and this value will be 
taken as the last result.

② 

Measure times setting

The statistic times can be set under this menu. The statistic times 
will increase 1 by one pressing of button “UP”. The statistic times 
will decrease 1 by one pressing of button “DOWN”. The continuous 
increasing or decreasing will be realized by keep pressing the 
button  UP” or “DOWN”. The maximum statistic times setting is 9.

 

 

10

Fig 4-15

  

② 

Backlight time setting

 Under this menu, the continued lighting time of the backlight can  
 be set.

0s: The backlight will be turned off all times
15s: The backlight lighting 15 second every time.
30s: The backlight lighting 30 second every time.
45s: The backlight lighting 45 second every time.
60s:  The backlight lighting 60 second every time.
Disable: the backlight will light all the time.
The selection will be modified by pressing button “UP” or “DOWN”. 
The selection will be confirmed by pressing button “OK”. The 
selection will be aborted by press button “RETURN”.

 

Key sound setting

The key sound can be turn on or off by this setting.

The selection will be modified by pressing button “UP” or “DOWN”. 
The selection will be confirmed by pressing button “OK”. The  
selection will be aborted by press button “RETURN”.

Fig 4-16

Fig 4-17

statistic times 

  

can't be set.

Fig 4-8

Summary of Contents for ISH-DSD

Page 1: ...ISH DSD www insize com OPERATION MANUAL DIGITAL SHORE DUROMETER MN ISH DSD E V0...

Page 2: ......

Page 3: ...foot surface The value of L indicates the value of Shore Hardness of the sample Larger the value of L smaller the Shore Hardness Conversely smaller the value of the L sample s Larger the sample s Shor...

Page 4: ...n flooring bowing Especially for on site hardness measurement of rubber and plastic products 15 2 Print report There are several print modes built in the durometer You can select by yourself 3 Auto pr...

Page 5: ...Low voltage alarming and recharge The durometer will be recharged by the packaged charger The durometer will not be auto power on during recharging The charging status will show on the measuring inter...

Page 6: ...e current times Measure mode Indicating the current measure mode AVE Average measure mode Max Maximum value measure mode MAX AVE Maximum average value measure mode 2 Menu 7 6 5 4 3 2 1 Fig 4 1 Hardnes...

Page 7: ...r this menu All data will be deleted by selection of YES and this operation will be aborted by selection of NO Fig 4 22 5 Print setting The data saved in the durometer can be printed by the thermal pr...

Page 8: ...ssing button UP The measure date time sample code of the current data can be shown pressing button OK 6 1 Calibration Pressing button OK to enter the menu select Calibration press button The durometer...

Page 9: ...tically The average value of maximum value of every measuring will be calculated and this value will be taken as the last result Measure times setting The statistic times can be set under this menu Th...

Page 10: ...l be button RETURN be aborted by press 8 Tolerance limit setting Under this menu the tolerance limit can be set When the measuring data is exceed the setting value the icon of will be showed on the LC...

Reviews: