insize ISH-DSD Operation Manual Download Page 6

4

 pressing this button. Under parameters setting interface, the value 
 will increase by pressing this button.

 UP: Under the menu interface, the selection will be shifted up by 

 by pressing this button. Under parameters setting interface, the 
 value will decrease by pressing this button. Under some parameters 
 setting interface, the selection will be moved down by pressing this 
 button.

 DOWN: Under the menu interface, the selection will be shifted down 

 2) Interface

 The large and high resolution LCD is applied to this durometer, so 
 this durometer has the advantage of fully information display and 
 easy to read etc.

 

 Battery level: Indicating the battery level or charging status
 Hardness value: The current measured hardness value
 Peak difference: The difference between the maximum value and 
 the minimum value of this data group
 Average value: the average value of this data group
 Statistic times: the measure times of one statistic group
 Current times: Indicating the current times 
 Measure mode: Indicating the current measure mode
 AVE: Average measure mode
 Max: Maximum value measure mode
 MAX AVE: Maximum average value measure mode

 2.  Menu

 

 

 

 

 

 

7

6

5

4

3

2

1

Fig 4-1

 Hardness tester has multi-level menu interface. The system setting 
 can be finished by simple operation. The menu structure is showed in 
 Figure 4-2. The first page of the main menu is showed in figure 4-3. 
 The second page of the main menu is showed in figure 4-4.

13

 ②

 

Print Items setting

 Whether the date/time will be print can be set under this menu.

Fig 4-24

 ③ 

Print the selected data

 Firstly, the range of data to be printed should be set. After the 
 setting is finished, the print command will be carried out by  
 pressing button “OK”. The print command will not be carried out  
 by pressing button  RETURN”.

Fig 4-25

 ④

 

Print all data

 The prompt window will be pushed out under this menu. All data
 will be printed by selection of “YES” and this operation will be  
 aborted by selection of “NO”.

Fig 4-26

 6) Software information

 The logo and software version will be showed under this menu.
 AABBCC on behalf of the date of manufacture: AA means year, BB 
 means month, CC means date.

Fig 4-27

Summary of Contents for ISH-DSD

Page 1: ...ISH DSD www insize com OPERATION MANUAL DIGITAL SHORE DUROMETER MN ISH DSD E V0...

Page 2: ......

Page 3: ...foot surface The value of L indicates the value of Shore Hardness of the sample Larger the value of L smaller the Shore Hardness Conversely smaller the value of the L sample s Larger the sample s Shor...

Page 4: ...n flooring bowing Especially for on site hardness measurement of rubber and plastic products 15 2 Print report There are several print modes built in the durometer You can select by yourself 3 Auto pr...

Page 5: ...Low voltage alarming and recharge The durometer will be recharged by the packaged charger The durometer will not be auto power on during recharging The charging status will show on the measuring inter...

Page 6: ...e current times Measure mode Indicating the current measure mode AVE Average measure mode Max Maximum value measure mode MAX AVE Maximum average value measure mode 2 Menu 7 6 5 4 3 2 1 Fig 4 1 Hardnes...

Page 7: ...r this menu All data will be deleted by selection of YES and this operation will be aborted by selection of NO Fig 4 22 5 Print setting The data saved in the durometer can be printed by the thermal pr...

Page 8: ...ssing button UP The measure date time sample code of the current data can be shown pressing button OK 6 1 Calibration Pressing button OK to enter the menu select Calibration press button The durometer...

Page 9: ...tically The average value of maximum value of every measuring will be calculated and this value will be taken as the last result Measure times setting The statistic times can be set under this menu Th...

Page 10: ...l be button RETURN be aborted by press 8 Tolerance limit setting Under this menu the tolerance limit can be set When the measuring data is exceed the setting value the icon of will be showed on the LC...

Reviews: