background image

Starter Replacement

SPECIFICATION / REPLACEMENT PARTS

Unit  

Aura

Voltage  

230V   ~   50Hz

Dimensions(mm) 

270 x 270 x 135 

Coverage 

40 Sq. Meters

Weight  

1.9 Kg 

Light Output 

22W 

Tubes

 

 

1 x TGX22 

Starter

   

1 x I154 

Glueboards (x6)

 INL198 

(Yellow) 

GLUEBOARD REPLACEMENT

BEFORE REPLACING THE GLUEBOARD, ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED FROM 

THE MAINS SUPPLY.

The glueboard should be replaced every month with a genuine glupac

®

 glueboard.  Use of 

non-approved glueboards may invalidate your guarantee.  

Aura

 

comes supplied with a high 

specification yellow glueboard with printed grids for simple insect evaluation and monitoring.  

To replace the glueboard…

 

1. Swing down the front guard.

 

2. Remove the used glupac

®

 glueboard by carefully pulling it clear of the unit.

 

3. Remove the protective release paper from the new glupac

®

 glueboard.

 

4. Maneuver the straight edges of the flat glueboard into the gap between the    

 

    horizontal guard and the vertical tube chassis.

 

5. Then maneuver the glueboard together to forma a conical shape and position the  

 

    glueboard under the ‘front’ two metal retaining clips.

 

6. Finally, tuck the two cardboard ‘corners’ of the glueboard under the ‘back’ two  

 

    metal retaining clips.   

Always ensure the selected genuine 

glupac

®

 glueboards are compatible with your unit, 

available from your pest control operator or P+L Systems Ltd.

TUBE REPLACEMENT

TUBE REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER ENSURING 

THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.

To ensure the efficiency of 

Aura

 in catching flying insects, the UV tube should be replaced 

annually.  After twelve months the phosphor coating that emits the correct wavelength of UV 

light has burnt away and the UV output is diminished substantially. 

To replace the UV tube…

 

1. Swing down the front guard.

 

2. Unclip the wire tube clips.

 

3. Pull the tube away from the chassis.

 

4. Dispose of the used UV tube in conjunction with local WEEE regulations.

STARTER REPLACEMENT

STARTER REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER 

ENSURING THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.

The starter provides an extra spark to initially light the UV tube.  The 

starter wears out and should be replaced at the same intervals as 

the UV tube.

To replace the starter…

 

1. Rotate the starter anti-clockwise.

 

2. Pull the starter free from the unit.

C

2011

P+L Systems Ltd

Information provided on these instructions is modified and 

updated from time to time.  This is due to the constant 

redevelopment of our products.  As such, it is not intended that 

you should rely on it or that it should form part of any contract.  

P+L Systems Ltd
Ten St James Business Park
Grimbald Crag Court
Knaresborough
HG5 8QB      UK

T  +44 (0)800 988 5359
F  +44 (0)1423 863 497
W  www.pandlsystems.com
E  [email protected]

R3  06/11 

Tube Replacement

WEEE Compliance No. 01576542

Glueboard Replacement

Reviews: