Starter Replacement
SPECIFICATION / REPLACEMENT PARTS
Unit
Aura
™
Voltage
230V ~ 50Hz
Dimensions(mm)
270 x 270 x 135
Coverage
40 Sq. Meters
Weight
1.9 Kg
Light Output
22W
Tubes
1 x TGX22
Starter
1 x I154
Glueboards (x6)
INL198
(Yellow)
GLUEBOARD REPLACEMENT
BEFORE REPLACING THE GLUEBOARD, ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED FROM
THE MAINS SUPPLY.
The glueboard should be replaced every month with a genuine glupac
®
glueboard. Use of
non-approved glueboards may invalidate your guarantee.
Aura
™
comes supplied with a high
specification yellow glueboard with printed grids for simple insect evaluation and monitoring.
To replace the glueboard…
1. Swing down the front guard.
2. Remove the used glupac
®
glueboard by carefully pulling it clear of the unit.
3. Remove the protective release paper from the new glupac
®
glueboard.
4. Maneuver the straight edges of the flat glueboard into the gap between the
horizontal guard and the vertical tube chassis.
5. Then maneuver the glueboard together to forma a conical shape and position the
glueboard under the ‘front’ two metal retaining clips.
6. Finally, tuck the two cardboard ‘corners’ of the glueboard under the ‘back’ two
metal retaining clips.
Always ensure the selected genuine
glupac
®
glueboards are compatible with your unit,
available from your pest control operator or P+L Systems Ltd.
TUBE REPLACEMENT
TUBE REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER ENSURING
THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
To ensure the efficiency of
Aura
™
in catching flying insects, the UV tube should be replaced
annually. After twelve months the phosphor coating that emits the correct wavelength of UV
light has burnt away and the UV output is diminished substantially.
To replace the UV tube…
1. Swing down the front guard.
2. Unclip the wire tube clips.
3. Pull the tube away from the chassis.
4. Dispose of the used UV tube in conjunction with local WEEE regulations.
STARTER REPLACEMENT
STARTER REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER
ENSURING THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
The starter provides an extra spark to initially light the UV tube. The
starter wears out and should be replaced at the same intervals as
the UV tube.
To replace the starter…
1. Rotate the starter anti-clockwise.
2. Pull the starter free from the unit.
C
2011
P+L Systems Ltd
Information provided on these instructions is modified and
updated from time to time. This is due to the constant
redevelopment of our products. As such, it is not intended that
you should rely on it or that it should form part of any contract.
P+L Systems Ltd
Ten St James Business Park
Grimbald Crag Court
Knaresborough
HG5 8QB UK
T +44 (0)800 988 5359
F +44 (0)1423 863 497
W www.pandlsystems.com
E [email protected]
R3 06/11
Tube Replacement
WEEE Compliance No. 01576542
Glueboard Replacement