Aura
™
Please read these instructions carefully and store in a safe place
for future reference.
Aura
™
As part of the
Insect-O-Cutor
®
brand of insect control products,
Aura
™
is a decorative professional flykiller which utilises a highly
effective
Synergetic
®
UV tube and is designed for use with a
high specification glupac
®
glueboard.
CONTENTS OF PACKAGE
- 1 x
Aura
™
flykiller
- 1 x glupac
®
pheromone impregnated glueboard
- 1 x Mains cable (Type X)
- 1 x High powered
Synergetic
®
UV tube (Fitted)
- 2 x Screws and wall plugs
- 1 x Hard wired blanking piece
WARNING - THIS APPLIANCE MUST BE EARTHED (CLASS 1)
INSECT CONTROL PRODUCTS
Aura
™
utilises a high powered ultra violet tube to attract flying
insects and retains the caught insects on a pheromone
impregnated glueboard for inspection or hygienic disposal.
WARNING
Aura
™
is not to be used by children or persons with reduced
physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or
instruction.
Children should be supervised to ensure they do not play with
the appliance.
If the mains cable is damaged it must be replaced by a
specialist mains cable available from P+L Systems Ltd or your
supplier.
POSITIONING AND GUIDANCE FOR USING
AURA
™
THIS UNIT IS FOR INDOOR USE ONLY.
For most species of flying insects,
Aura
™
should ideally be fixed
around two meters above the ground, preferably in the darkest
place within the area to be protected. Do not position the unit
close to windows, skylights or other sources of light, or where it
may be obscured by furniture, doors or other obstacles. Ideally,
Aura
™
should be visible from every part of the area to be
protected.
However, due to its unique circular design,
Aura
™
can also be
mounted low to the ground, ideal for catching drain flies without
revealing the caught insects to customers.
Aura
™
should ideally be in operation for 24 hours a day, ensuring
your premises are kept free of flying insects. Insects are most
attracted to
Aura
™
at night when there is no competition from
daylight or other light sources.
GUARANTEE
Aura
™
has a two year guarantee and if maintained as
recommended in these instructions should continue to work for
many years.* Use of non-approved consumables may invalidate
the guarantee. Ensure genuine glupac
®
glueboards are used in
conjunction with this product.
*Excludes tube, glueboard and starter. Does not cover breakdown due to misuse, incorrect
operation or use in an incorrect application.
INSTALLATION
INSTALLATION SHOULD BE CARRIED OUT BY SERVICE PERSONNEL
ONLY, AFTER ENSURING THAT THE UNIT IS DISCONNECTED FROM
THE MAINS SUPPLY.
Aura
™
has a swing down front guard for easy access to replace
the
Synergetic
®
UV tube, glupac
®
glueboard and starter.
Aura
™
can either be wall mounted by using the two supplied wall
screws or simply located horizontally on a desk.
If wall mounting
Aura
™
, either simply use the supplied removable
IEC mains cable to plug into the nearest power socket, or use the
discreet hard wiring option to provide power directly from a
fixed power supply.
BEFORE HARD WIRING, ENSURE THE MAINS POWER SUPPLY IS
SWITCHED OFF.
For hard wiring, first mark the two fixing points using the ‘Hard
Wired Wall Mount Template’ on the enclosed sheet, before
installing the wall plugs and fixing screws. Remove the front
metal plate of the product by unscrewing the three retaining
fixing screws.
(fig 1)
Then remove the three short connection
wires which connect the IEC socket to the terminal block by
pressing the three spring retainers.
(fig2) & (fig 3)
Cover the
redundant IEC socket with the supplied blanking piece.
(fig 4)
Next, carefully remove the ‘knock out’ section of the plastic
backplate with a knife, creating the hard wired mains entry port.
(fig 5)
Offer the unit up to the two wall screws and feed the
mains wire through the newly created entry port.
(fig 6)
Insert
the live, neutral and earth wires into the appropriate spring
retainers.
(fig 7)
Finally replace the front metal plate,
(fig 8)
before swinging the front guard back in position.
(fig 9)
CLEANING
CLEANING
SHOULD BE CARRIED OUT BY SERVICE PERSONNEL
ONLY, AFTER ENSURING THAT THE UNIT IS DISCONNECTED FROM
THE MAINS SUPPLY.
It is recommended that cleaning is carried out regularly when
the glueboard is replaced. Once the glupac
®
glueboard is
removed, the unit should be thoroughly wiped down with a
damp cloth, removing any build up of dirt. Ensure the unit is
completely dry before reconnecting it to the power supply.
Professional Glueboard Insect Control
MOUNTING FIXING CENTRES
METHOD
Aura
Wall
80mm
Desk
-
Mounting Options
Wall Desk