Inscape Data LinkPower LPS1800 Series User Manual Download Page 1

 

 

 

LinkPower

 LPS1800 Series             

IP Management User’s Manual 

May, 2015

 

 

 

Corporate Headquarters 

Inscape Data Corporation 

1620 Oakland Road D101 

San Jose, CA 95131   

U.S.A.

 

Website: http://www.inscapedata.com 
 

Main: 408 392-9800 

Fax: 408 392-9812

 

Summary of Contents for LinkPower LPS1800 Series

Page 1: ...S1800 Series IP Management User s Manual May 2015 Corporate Headquarters Inscape Data Corporation 1620 Oakland Road D101 San Jose CA 95131 U S A Website http www inscapedata com Main 408 392 9800 Fax...

Page 2: ...ely to cause harmful interference in which case the user will be required to correct the interference at his own expense The user is cautioned that changes and modifications made to the equipment with...

Page 3: ...s used in Hardware replacement may be new or equivalent to new Inscape Data s obligations hereunder are conditioned upon the return of affected Hardware in accordance with Inscape Data s or its servic...

Page 4: ...XCLUDED TO THE EXTENT ALLOWED BY APPLICABLE LAW AND ARE EXPRESSLY DISCLAIMED BY INSCAPE DATA ITS SUPPLIERS AND LICENSORS TO THE EXTENT AN IMPLIED WARRANTY CANNOT BE EXCLUDED SUCH WARRANTY IS LIMITED I...

Page 5: ...e Warranty One 1 Year Replacement Repair or Refund Procedure for Hardware Inscape Data or its authorized service center will use commercially reasonable efforts to ship a replacement part after receip...

Page 6: ...MENTAL LICENSE AGREEMENT THE SUPPLEMENTAL LICENSE AGREEMENT SHALL APPLY BY DOWNLOADING INSTALLING OR USING THE SOFTWARE YOU ARE BINDING YOURSELF AND THE BUSINESS ENTITY THAT YOU REPRESENT COLLECTIVELY...

Page 7: ...ROM or on line In order to use the Software Customer may be required to input a registration number or product authorization key and register Customer s copy of the Software online at Inscape Data s...

Page 8: ...expressly permitted under applicable law notwithstanding this restriction iv publish any results of benchmark tests run on the Software v use or permit the Software to be used to perform services for...

Page 9: ...written permission of Inscape Data Term and Termination The Agreement and the license granted herein shall remain effective until terminated Customer may terminate the Agreement and the license at an...

Page 10: ...ause to the contrary in any agreement into which the Agreement may be incorporated Customer may provide to Government end user or if the Agreement is direct Government end user will acquire the Softwa...

Page 11: ...arranty does not apply if the Software Product or any other equipment upon which the Software is authorized to be used a has been altered except by Inscape Data or its authorized representative b has...

Page 12: ...R SUCH OTHER PRODUCT THIS LIMITATION OF LIABILITY FOR SOFTWARE IS CUMULATIVE AND NOT PER INCIDENT I E THE EXISTENCE OF TWO OR MORE CLAIMS WILL NOT ENLARGE THIS LIMIT IF YOU ACQUIRED THE SOFTWARE IN EU...

Page 13: ...E ABOVE LIMITATION MAY NOT APPLY TO YOU IF YOU ACQUIRED THE SOFTWARE IN JAPAN EXCEPT FOR LIABILITY ARISING OUT OF OR IN CONNECTION WITH DEATH OR PERSONAL INJURY FRAUDULENT MISREPRESENTATION AND REGARD...

Page 14: ...liability set forth herein that the same reflect an allocation of risk between the parties including the risk that a contract remedy may fail of its essential purpose and cause consequential loss and...

Page 15: ...l law the Agreement and Warranties are controlled by and construed under the laws of the State of California United States of America notwithstanding any conflicts of law provisions and the state and...

Page 16: ...t To minimize shock hazard the instrument chassis and cabinet must be connected to an electrical ground The instrument must be connected to the ac power supply mains through a three conductor power ca...

Page 17: ...that services the device switch the circuit breaker to the OFF position and tape the switch handle of the circuit breaker in the OFF position Work During Lightning Activity Do not work on the system...

Page 18: ...4 2 4 Load Default Setting 25 2 5 Firmware Update Upgrade 26 2 6 Reboot Device 27 Chapter 3 Port Setting 29 3 1 Port Configuration 29 3 2 Port Mirroring 30 3 3 Bandwidth Control 31 3 4 Broadcast Storm...

Page 19: ...ion 47 10 1 DHCP Relay Agent Setting 47 10 2 Relay Server Setting 47 10 3 VLAN MAP Relay Agent Setting 47 Chapter 11 Configuration Backup Recovery 49 11 1 Configuration Backup Recovery 49 Chapter 12 M...

Page 20: ...Settings VLAN QoS Settings and so on various system configurations Reader objects This manual requires a certain network knowledge from the user such as understanding of a network device and be famili...

Page 21: ...this device support WEB management equipment IP management by default 192 168 2 1 subnet mask 255 255 255 0 the default gateway 192 168 2 254 The administrator of the PC as long as you can communicate...

Page 22: ...n main page Note Default login ID admin and login password system Corresponding user name and password can be modified in the password setting After successfully login the main page is displayed as be...

Page 23: ...n in the directory Administrator of the switch management on the left side go to the following page This page is used to modify the current login user name and password Click Update configuration If y...

Page 24: ...re the IP Address Subnet Mask Gateway and IP Configure of the switch IP address configuration can t be all zeros all F and multicast address Click Update configuration after the success of the configu...

Page 25: ...ge 2 4 Load Default Setting Restore the default value of the switch configuration back to the initial state but does not include the IP address of the device the user name and password Click Load Defa...

Page 26: ...and confirm the same as the user password click Update to enter the flash erase page after the flash erase will pop up the following page Click on the browse select the upgrade file that you need in t...

Page 27: ...put file path filename Bin press the return key As shown in figure Please log in again after the completion of systems Note The default update password is 123456 If return an error or the time for up...

Page 28: ...Page 28 Revision 1 0 Click Confirm...

Page 29: ...Auto Negotiation speed rate Speed Duplex mode Duplex flow control 802 3 x backpressure and port learning Addr Learning function In the Select Port No Port check the configuration on the function of th...

Page 30: ...g port used to analyze and monitor packets As shown below the destination port Dest Port select the mirror port in Source Port Source Port is selected to be mirrored port Prison probe type Monitored P...

Page 31: ...follows Low 32Kbps and High 512Kbps The formula maximum transmit receive rate Rate control 0 255 x 32 kbps low bandwidth Rate control 0 255 x 512 kbps high bandwidth Click Submit Update is configured...

Page 32: ...bandwidth control rate the system will be connected rate as bandwidth control rate 3 4 Broadcast Storm Control As shown in Port Enable Enable Port the selected configuration port it says the maximum...

Page 33: ...Page 33 Revision 1 0...

Page 34: ...Port based VLAN and Tag Base VLAN The default mode is the Port based VLAN mode The following figure Click Change VLAN Mode can be switched systems VLAN mode In the Tag Base VLAN mode page the user can...

Page 35: ...tion to end is a PC card generally it s unable to identify 802 1 Q Tag In this case please set the corresponding port to Untagged properties 4 2 VLAN Member Based on the system VLAN mode can be divide...

Page 36: ...01 to 15 to be the downlink ports so that the port 16 of the switch will forward the packets to the port 01 to 15 of the switch The Configuration is shown below Click Restore Default Load Default to r...

Page 37: ...types the Receive Packet Transmit Packet the Transmit Packet Collision Count the Receive Packet Drop the Packet and the Receive Packet CRC error Packet After choosing type click the submit Update can...

Page 38: ...Page 38 Revision 1 0 Note system does not automatically refresh the count must manually click on the refresh When the count value reaches the maximum value will be reset automatically...

Page 39: ...e scheduling All High Before Low in strict accordance with the order of the priority from High to Low priority to send groups of higher priority queue when the higher priority queue is empty and then...

Page 40: ...port can be bound 3 groups of MAC address the binding of MAC message will not be forwarded For example Select port selected 01 Binding selected enable MAC Address selected 00 0 a 5 a 01 01 01 after th...

Page 41: ...essage other protocol Port packet is discarded Secure Port is said set TCP UDP filtering function switches WAN Port Protocol includes 20 different network protocols In addition UserDEF_a UserDEF_b and...

Page 42: ...Chapter 8 Spanning Tree Settings 8 1 STP Bridge Settings There is an example of STP Bridge Setting STP mode disable stp rstp Bridge Priority 0 61440 Hello Time 1 10 seconds Max Age 6 40 seconds Forwar...

Page 43: ...Page 43 Revision 1 0 8 2 STP Port Settings 1 STP Port Settings To set port priority and port path cost 2 STP Port Status To display port path cost priority forward status STP port states and so on...

Page 44: ...Page 44 Revision 1 0...

Page 45: ...0 8 3 Loopback Detection Settings 1 Loopback Detect Function Enable on Disable off 2 Auto Wake Up Enable on Disable off 3 Wake Up Time Interval Open Auto wake up there are loop of ports Discard the du...

Page 46: ...ided into four strategies the port ID SA DA and SA DA as per hash logic relations based on relations System by default is the port ID type Note alone choose a port as Link Aggregation is void Settings...

Page 47: ...ange is 1 16 DHCP Relay Option 82 state when selecting Enable its function is on when selecting Disable it s off 10 2 Relay Server Setting Add the Relay Server can add up to three Relay Server Enter t...

Page 48: ...Page 48 Revision 1 0 click Add...

Page 49: ...the local in Bin file format 2 Configuring Recovery Click on the Browse the file selection box will pop up open the configuration file in the corresponding local path Input password the default passw...

Page 50: ...ms 400 ms 600 ms and 800 ms Disable shows no aging 2 VLAN Striding After the feature enabled even two ports are not in the same VLAN the switch will also forward destination MAC known single broadcast...

Page 51: ...Page 51 Revision 1 0...

Page 52: ...ld down the RESET button loosen after 5 seconds The switch will automatically restore the default Settings you can see the System LED flashing After the system LED restore normal flashing frequency i...

Page 53: ...n Switches and network terminal Ethernet ports don t match each other Network setup is not correct Set the Ethernet ports working mode to make it match or set it to be adaptive work mode Check the net...

Page 54: ...thernet based on 4B 5B signal coding and the use of two pair Cat5 twisted pair cable 100BASE FX EEE802 3 short terminology said 100 Mbps fast Ethernet based on 4B 5B signal coding Automatic Negotiatio...

Page 55: ...ctrical connection MDIX Cross media interface it can send the sending signal of a device to the receiving end of another device and vice versa RJ 45 A 8 pin module connector used in Twisted pair link...

Page 56: ...1 to 8 in turn Table 1 shows the function definition of each pin about the RJ 45 connector on the MDI mode function Table 2 shows the function definition of each pin about the RJ 45 connector on the...

Page 57: ...iving data 2 RxData receiving data 3 TxData sending data 4 reserve 5 reserve 6 TxData sending data 7 reserve 8 reserve Network Cable Production Chart 2 Cat 5 twisted pair cable schematic diagram Pair...

Page 58: ...requirements should choose respectively In the traditional network when the LAN cards connect with the hubs switches and so on using straight through cable When the connection between LAN card and LA...

Page 59: ...on SIDE1 SIDE1 SIDE2 1 2 3 4 5 6 7 8 1 white orange 1 white green 2 orange 2 green 3 white green 3 white orange 4 blue 4 blue 5 white blue 5 white blue 6 green 6 orange 7 white brown 7 white brown 8 b...