7.6

 

ACCUMULATION WHEN IN PARTS COUNTING  

 

 

When  in  parts  counting  mode,  the  values  (weight  and  count)  shown  on  the 
display can be added to the values in the accumulator by pressing the

 [M+/

↵↵

key. The 

“Weight”

 display will show the number of times. The 

“Total”

 display 

will show the total accumulated count. 

 

 

More  products  can  then  be  added  and  the

  [M+/

↵↵

key  to  be  pressed  again. 

This  can  continue  for  up  to  99  entries  or  until  the  capacity  of  the 

“Weight”

 

display is exceeded. 

 

 

To observe the total stored times and count value, press the

 [Total] 

key.  

 

 

 

Press the

[M+/

↵↵

]  

key

 

will return to the normal weighing . 

7.7  BACKLIGHT FOR LCD 

 

 

The backlight of the LCD can be set to be light or dark. 

 

When in normal weighing mode press the 

[Sample /Blight]

 key to change the 

state of the backlight. 

 

8.0  FUNCTION

 

SETTING 

8.1

 

ENTERING

 

THE

 

FUNCTION

 

SETTING

 

MODE 

 

 

To enter the parameter menu, hold

  [Zero] 

and press the

  [Tare] 

key when in 

normal weighing mode.    

 

The display will  show the revision number in the 

“Weight” 

display ,The

 “Unit 

Weight”

  display  will  show

  "-  - - -     "

  requesting  the  password  number  to  be 

entered.  

 

 

The  default  password  is 

"0000" 

but  other  numbers  can  be  set  using  the 

parameter  menus.  Press  the 

[0]

  key  four  times.  The  display  will  jump  to  the 

first  parameter.     

"FILt ?" 

with  the  Unit  weight  window  showing  the  current 

filter setting. 

 

Summary of Contents for IBC-15

Page 1: ...Inscale Ltd 2011 IBC SERIES Pn 700660168 RevisionC August 2011...

Page 2: ...Inscale Ltd 2011 Easy Reference Model name of the scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and place...

Page 3: ...SPLAY 8 5 2 UNIT WEIGHT DISPLAY 8 5 3 TOTAL DISPLAY 8 6 0 KEY DESCRIPTIONS 9 7 0 WEIGHING 9 7 1 BEFORE WEIGHING 9 7 2 WEIGHING 9 7 3 ZEROING THE DISPLAY 9 7 4 TARING 10 7 5 PARTS COUNTING 10 7 6 ACCUM...

Page 4: ...Inscale Ltd 2011 p a g e 2...

Page 5: ...operation Four models 3kg X 0 1g 6kg X0 2g 15kg X 0 5g 30kg X 1g Large LCD with backlight 3 weighing units g kg lb Indicators for Stable zero net weight and low battery functions Stainless steel pan...

Page 6: ...Inscale Ltd 2011 p a g e 4...

Page 7: ...0 2g 0 5g 1g Repeatability 0 1g 0 2g 0 5g 1g Linearity 0 2g 0 4g 1g 2g Units kg g lb Stabilization time 2s 2s 2s 2s Operating temperature 0 C to 40 C 32 F to 104 F Power supply 12VDC 800mA adapter 6V...

Page 8: ...be removed if the scale is not used for a long period of time Do not stack material on the scale when it is not in use Avoid high humidity that might cause condensation and keep away from direct cont...

Page 9: ...ould be adjusted such that the bubble in the spirit level is in the centre of the level and the scale is supported by all four feet Attach the power supply cable to the connector on the right side of...

Page 10: ...ator Zero Stability indicator Stable Indicators for the changed units kg g lb 5 2 UNIT WEIGHT DISPLAY This display will show the unit weight of a sample This value is either input by the user or compu...

Page 11: ...e value from the weight and shows the results This is the net weight Entering a value using the keypad will store that as the tare value Zero Sets the zero point for all subsequent weighing It shows z...

Page 12: ...roduct was to be added to the first one Again only the weight that is added after taring will be displayed 7 5 PARTS COUNTING In order to do parts counting it is necessary to know the average weight o...

Page 13: ...and the quantity will increase If the function ASPL is enabled see section 6 1 the unit weight will be automatically recalculated when an additional mass less than the current count is added If the sc...

Page 14: ...key Press the M key will return to the normal weighing 7 7 BACKLIGHT FOR LCD The backlight of the LCD can be set to be light or dark When in normal weighing mode press the Sample Blight key to change...

Page 15: ...e to be used to determine zero tracking range of 0 5d 1d 2d 4d or Off A larger number means larger range of zero tracking and a worse repeatability the default is 1d CodE Use the keypad to set a new p...

Page 16: ...en calibrating after 6 presses Ignore this function unless yu want to change the weighing unit during calibration Press the numeric keys to enter the calibrate mass value For kilograms and pounds ente...

Page 17: ...Inscale Ltd 2011 p a g e 15 10 0 ERROR MESSAGE Z ERR A D counts are too high or low EEEEE Overload 9d Arrow above Lo Bat Low battery indication...

Page 18: ...Inscale Ltd 2011 p a g e 16...

Page 19: ...in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with...

Page 20: ...listing of all Inscale products visit our website at www inscale co uk Copyright by inscale Ltd All rights reserved No part of this publication may be reprinted or translated in any form or by any mea...

Reviews: