— 21 — 

You may mouse-over the BandScanner display screen and click 

on  any  vertical  bar.    The  radio  will  tune  to  that  station  and  

bring up the 

Now Playing

 page. 

ALARMS 

Alarm Status 

Signal-related  alarms  light  front-panel  LEDs  and  give  flashing 

notifications on the front-panel OLED screen.  The front-panel 

LEDs are also reflected on the 

Now Playing

 page and in the 

Alarm 

Status

  area  of  this  Web  

interface page as shown 

here.    Any  or  all  alarms  

are also able to initiate 

email or SMS/text messages to selected personnel, and alarms 

are logged for later analysis or finger-pointing.  Alarms are also 

assignable to rear-panel GPO ‘tally’ outputs to interface with 

remote-control equipment or local lights and sirens. 

Front-panel LEDs will begin blinking immediately upon register-

ing  an  alarm  magnitude-related  condition  (warning),  and  will  

light  steadily  once  the  alarm  timing  condition  has  been  met  

(alarm).  Alarm conditions must first be set-up as described in 

the  remainder  of  this  section.    Following  that,  the  email/SMS  

messaging and rear-panel GPO tallies may be programmed.  

These procedures will be described in the 

Setup 

and 

Email

 

Webpage discussions, respectively. 

NOTE:

  Do please read the following discussions in their entire-

ty.    A  setup  explained  for  one  alarm  that  is  common  (or  quite  

similar) to the setup of others may not be repeated in full detail 

a second time. 

Audio Loss 

Alarm:  On

    simply 

‘arms’ the function 

for  loss  of  audio.  

With 

Alarm: Off

 se-

lected,  there  will 

be  no  front-panel 

AUDIO LOSS

  LED 

or  corresponding 

Web interface indi-

cator   on   the  

Now 

Playing

  or 

Alarm

 

pages.    There  will  be  no  closure  at  a  rear-panel  GPO  terminal,  

nor will the SOFIA 567 send SMS/text or Email alerts to station 

personnel or log the alarm.  This applies to all alarms. 

Level (dB):

 displays the current audio metering level of the off-

air program being received.  This is ‘grayed-out’ because there 

is no adjustment to make in this case.  The audio level is shown 

to make alarm setup easier. 

Summary of Contents for AM SiteStreamer+ SOFIA 567

Page 1: ...SOFIA 567 AM SiteStreamer Installation User Guide www inovonicsbroadcast com...

Page 2: ......

Page 3: ...0 0 0 Inovonics Inc 5805 Highway 9 Felton CA 95018 Tel 831 458 0552 Fax 831 458 0554 Register online at www inovonicsbroadcast com PRODUCT REGISTRATION RECORD SOFIA 567 Serial No _____________ Purchas...

Page 4: ...2...

Page 5: ...ns Power 10 Radio Frequency Interference RFI 10 Ground Loops 10 INPUTS OUTPUTS AND PORTS Antenna Input and Considerations 10 Analog Line Outputs 10 Unbalanced Operation 11 AES Digital Line Output 11 A...

Page 6: ...ING Audio Level Metering 18 Histograms 19 The BandScanner Utility 20 ALARMS Alarm Status 21 Audio Loss 21 Low Signal 22 Overmodulation 22 Alarm Logging 22 SETUP Radio Settings 23 Audio Outputs 23 Gene...

Page 7: ...p 29 Recipients Send To 29 Notifications Send What 30 TIME SETUP Time and DST 30 Presentation Formats 30 RTC Battery 31 Time Server 31 ADMINISTRATIVE MATTERS Security and Passwords 31 Signing In 31 Lo...

Page 8: ...ll digital SDR Software Defined Radio off air re ception of medium wave analog AM stations Stays on channel and holds user settings through sig nal and power losses Provides analog AES3 digital Web st...

Page 9: ...10 sim ultaneous listeners Alarms Audio Loss Silence Sensor Alarm has programmable On Off thresholds and Time On Off intervals Low Signal Alarm and reset trigger levels are independently adjustable r...

Page 10: ...ake the product almost entirely DSP based with virtually all functionality provided through firmware coding The Block Diagram pre sented here illustrates product basics in an easily understood form al...

Page 11: ...g damage sustained due to improper packing for return may invalidate the Warranty IT IS IMPORTANT to register the Warranty of your SOFIA 567 This assures coverage of the equipment under Warranty terms...

Page 12: ...e optional rack mount chassis should satisfy this requirement INPUTS OUTPUTS AND PORTS Antenna Input and Considerations The rear panel ANTENNA input is a BNC female a ubiquitous connector worldwide wi...

Page 13: ...Port and Levels The Dante compliant AoIP Audio over Internet Protocol out put appears at the rear panel RJ45 AoIP PORT This port is in dependent of the SOFIA 567 LAN PORT network connection The AoIP...

Page 14: ...ary to get the unit up and running THE SOFIA 567 FRONT PANEL All setup and operating adjustments of the SOFIA 567 are un der firmware control There are no jumpers switches or me chanical potentiometer...

Page 15: ...ng on Page 21 Level Meters LED segment meters E are marked LEFT and RIGHT signifying the two dual mono program audio outputs that deliver an identical signal to both output connectors These are audio...

Page 16: ...p Radio De Emphasis select Spacing select Audio Outputs Analog Level select Digital Level select AoIP Level select General Purpose Outputs Output 1 4 select Type select Polarity set Status display Net...

Page 17: ...address information turn the knob to scroll down Assigning a Fixed IP Address To assign the SOFIA 567 a fixed IP address clear the DHCP box and then navigate through the various fields on this screen...

Page 18: ...casual au dio streaming Web listening plus the separate AoIP streaming utility and the rear panel analog and AES digital program line outputs In other words whatever station you tune will be heard on...

Page 19: ...n this ar ea of the Now Playing Webpage and on the Alarms Webpage where the alarm trigger and reset parameters are set Alarm specifics and setup procedures begin on Page 21 In addition to the alarm st...

Page 20: ...e off settings that will dictate the Rotation Time Sec setting See the Alarms discus sion beginning on Page 21 The Status display gives a second by second countdown of ro tation time GRAPHS METERING A...

Page 21: ...k anywhere in the display area to cycle through the options The upper graph shows program level over the selected time period The level reflects the unit s peak weighted metering and although it does...

Page 22: ...nge of interest NOTE The band scanning function mutes the receiver audio during the scan cycle and will put a glitch in the histograms as it actually tunes across the band and downloads data from each...

Page 23: ...s been met alarm Alarm conditions must first be set up as described in the remainder of this section Following that the email SMS messaging and rear panel GPO tallies may be programmed These procedure...

Page 24: ...squelched silenced during the alarm interval Mute On keeps random no carrier noise from making a nui sance of itself when the incoming signal is lost The RSSI dBuV grayed out bargraph gives the level...

Page 25: ...entries on a num ber of the Web interface pages The specific items on the Setup page are discussed in order here Radio Settings NRSC is the default De Emphasis setting NRSC de emphasis is a truncated...

Page 26: ...peaker icon at the top of each SOFIA 567 Web interface page which can be clicked on by as many as 10 users at the same time who have Internet access to the unit The streaming Format defaults to the po...

Page 27: ...ungrounded when the alarm is received The other GPOs are programmed in identical fashion The Status line in this example shows that Output 1 is Inactive that is the assigned Audio Loss alarm has not...

Page 28: ...ive in this instance Non Windows browsers may require you to enter the complete IP address of the unit which you can always find by front panel navigation to Setup Network IP Settings Incoming Interne...

Page 29: ...ndard from the Audio En gineering Society specifies a 48kHz sample rate but Dante en coding can send at a 44 1kHz rate as well perhaps a more common rate in radio broadcast plants But with AES67 Enabl...

Page 30: ...SNMP submenu default Mode setting is Disabled which in hibits communication between the SOFIA 567 and the SNMP Manager Changing Mode to Read Only allows the SOFIA 567 to be inter rogated by the SNMP...

Page 31: ...mail under SMTP Settings You need to set up an actual email account the elements of which are just like setting up any con ventional email account Information to be entered here de pends on the provi...

Page 32: ...d with this Recipient proceed to the next A Save command is not necessary in this operation TIME SETUP Time and DST The onboard Real Time Clock will re ceive updates from Internet Time daily and has s...

Page 33: ...only trusted and authorized logged in users will be able to view those screens Once the password is saved no Web interface screen is accessi ble And on the front panel Now Playing will be the only sc...

Page 34: ...rofile The entire SOFIA 567 setup may be saved to your computer as a small text file The Hardware Profile includes user settings alarm notification entries SNMP options etc and is useful for restoring...

Page 35: ...fresh Hardware Profile as a firmware update may affect user settings If there is danger of compromising stored data the firmware update will include notes to that effect Updates are issued as small b...

Page 36: ...34...

Page 37: ...ion label has been removed or altered III TERMS OF WARRANTY Inovonics Inc products are warranted to be free from defects in materials and workmanship A Any discrepancies noted within THREE YEARS of th...

Page 38: ......

Reviews: