If you dawdle or simply walk away, after 30 seconds of no fur-

ther knob activity the SOFIA 567 will enter a selection you have 

made into memory automatically, or simply ‘deselect’ the high-

lighted item with no changes if the setting has not been altered. 

The BACK 

Button 

BACK

  button 

B

  will  always  return  you  to  the  previous  menu  

screen.  Push it repeatedly to go back to the Main Menu shown 

in the illustration. 

If  you  make  a  mistake  (for  example,  you  might  

push

  the  knob  

slightly off-center, causing it to rotate and bring up the wrong 

menu), simply push the 

BACK

 button to return to the previous 

menu and try again.  

Graphic 

Display 

OLED  graphic  display  screen 

C

  presents  an abbreviated,  intui-

tive  setup  menu  tree  in  an  easy-to-follow  format.    The  display  

uses  a  screen  saver,  so  if  the  screen  goes  dim  or  dark,  simply  

push

  the  jog-wheel  knob  or  

BACK

  button  once  to  bring  the  

screen  back  to  life.    No  selection  or  change  is  made  with  this  

wakeup call. 

Local Alarms 

Front-panel  alarm  LEDs 

D

  indicate  critical  reception  errors.  

Programming the alarm thresholds and delays is accomplished 

through the Web interface as described starting on Page 21. 

  Level Meters 

LED-segment meters 

E

 are marked 

LEFT

 and 

RIGHT

, signifying 

the  two  ‘dual  mono’  program  audio  outputs  that  deliver  an  

identical  signal  to  both  output  connectors.    These  are  audio  

level indicators with 

peak

 

response

 to program dynamics. 

Please refer to Page 18 for a complete discussion of the audio 

level metering utility and its caveats. 

Menu Timeout 

and Screensaver 

After  making and saving  a setting,  you  may  press  the  

BACK

 

button to return to the Main Menu screen, or simply leave any 

current screen showing. 

A  programmed  interval  may  be  set  under  the  

Admin / Display

 

menu  to  adjust  screen  brightness  and  to  dim  or  turn  off  the  

OLED screen when the SOFIA 567 is unattended.  This is a rec-

ommended  practice  that  prolongs  the  life  of  the  display.    At  

any  time,  however  you  can  press  the  jog-wheel  knob  or  

BACK

 

button to wake the screen. 

THE FRONT-PANEL MENU TREE 

The several levels of front-panel setup and operating menus are 

laid  out  in  an  intuitive  and  easy-to-manage  fashion.    The  com-

plete Menu Tree is detailed below.  Keep in mind that the front-

panel Menu Tree is an abbreviated version of total SOFIA 567 

setup and operation navigation. 

Menu Titles

 are shown here in a font similar to the OLED display 

font.  Primary menu items are against the left margin and sub-

menu levels are indented appropriately. 

Summary of Contents for AM SiteStreamer+ SOFIA 567

Page 1: ...SOFIA 567 AM SiteStreamer Installation User Guide www inovonicsbroadcast com...

Page 2: ......

Page 3: ...0 0 0 Inovonics Inc 5805 Highway 9 Felton CA 95018 Tel 831 458 0552 Fax 831 458 0554 Register online at www inovonicsbroadcast com PRODUCT REGISTRATION RECORD SOFIA 567 Serial No _____________ Purchas...

Page 4: ...2...

Page 5: ...ns Power 10 Radio Frequency Interference RFI 10 Ground Loops 10 INPUTS OUTPUTS AND PORTS Antenna Input and Considerations 10 Analog Line Outputs 10 Unbalanced Operation 11 AES Digital Line Output 11 A...

Page 6: ...ING Audio Level Metering 18 Histograms 19 The BandScanner Utility 20 ALARMS Alarm Status 21 Audio Loss 21 Low Signal 22 Overmodulation 22 Alarm Logging 22 SETUP Radio Settings 23 Audio Outputs 23 Gene...

Page 7: ...p 29 Recipients Send To 29 Notifications Send What 30 TIME SETUP Time and DST 30 Presentation Formats 30 RTC Battery 31 Time Server 31 ADMINISTRATIVE MATTERS Security and Passwords 31 Signing In 31 Lo...

Page 8: ...ll digital SDR Software Defined Radio off air re ception of medium wave analog AM stations Stays on channel and holds user settings through sig nal and power losses Provides analog AES3 digital Web st...

Page 9: ...10 sim ultaneous listeners Alarms Audio Loss Silence Sensor Alarm has programmable On Off thresholds and Time On Off intervals Low Signal Alarm and reset trigger levels are independently adjustable r...

Page 10: ...ake the product almost entirely DSP based with virtually all functionality provided through firmware coding The Block Diagram pre sented here illustrates product basics in an easily understood form al...

Page 11: ...g damage sustained due to improper packing for return may invalidate the Warranty IT IS IMPORTANT to register the Warranty of your SOFIA 567 This assures coverage of the equipment under Warranty terms...

Page 12: ...e optional rack mount chassis should satisfy this requirement INPUTS OUTPUTS AND PORTS Antenna Input and Considerations The rear panel ANTENNA input is a BNC female a ubiquitous connector worldwide wi...

Page 13: ...Port and Levels The Dante compliant AoIP Audio over Internet Protocol out put appears at the rear panel RJ45 AoIP PORT This port is in dependent of the SOFIA 567 LAN PORT network connection The AoIP...

Page 14: ...ary to get the unit up and running THE SOFIA 567 FRONT PANEL All setup and operating adjustments of the SOFIA 567 are un der firmware control There are no jumpers switches or me chanical potentiometer...

Page 15: ...ng on Page 21 Level Meters LED segment meters E are marked LEFT and RIGHT signifying the two dual mono program audio outputs that deliver an identical signal to both output connectors These are audio...

Page 16: ...p Radio De Emphasis select Spacing select Audio Outputs Analog Level select Digital Level select AoIP Level select General Purpose Outputs Output 1 4 select Type select Polarity set Status display Net...

Page 17: ...address information turn the knob to scroll down Assigning a Fixed IP Address To assign the SOFIA 567 a fixed IP address clear the DHCP box and then navigate through the various fields on this screen...

Page 18: ...casual au dio streaming Web listening plus the separate AoIP streaming utility and the rear panel analog and AES digital program line outputs In other words whatever station you tune will be heard on...

Page 19: ...n this ar ea of the Now Playing Webpage and on the Alarms Webpage where the alarm trigger and reset parameters are set Alarm specifics and setup procedures begin on Page 21 In addition to the alarm st...

Page 20: ...e off settings that will dictate the Rotation Time Sec setting See the Alarms discus sion beginning on Page 21 The Status display gives a second by second countdown of ro tation time GRAPHS METERING A...

Page 21: ...k anywhere in the display area to cycle through the options The upper graph shows program level over the selected time period The level reflects the unit s peak weighted metering and although it does...

Page 22: ...nge of interest NOTE The band scanning function mutes the receiver audio during the scan cycle and will put a glitch in the histograms as it actually tunes across the band and downloads data from each...

Page 23: ...s been met alarm Alarm conditions must first be set up as described in the remainder of this section Following that the email SMS messaging and rear panel GPO tallies may be programmed These procedure...

Page 24: ...squelched silenced during the alarm interval Mute On keeps random no carrier noise from making a nui sance of itself when the incoming signal is lost The RSSI dBuV grayed out bargraph gives the level...

Page 25: ...entries on a num ber of the Web interface pages The specific items on the Setup page are discussed in order here Radio Settings NRSC is the default De Emphasis setting NRSC de emphasis is a truncated...

Page 26: ...peaker icon at the top of each SOFIA 567 Web interface page which can be clicked on by as many as 10 users at the same time who have Internet access to the unit The streaming Format defaults to the po...

Page 27: ...ungrounded when the alarm is received The other GPOs are programmed in identical fashion The Status line in this example shows that Output 1 is Inactive that is the assigned Audio Loss alarm has not...

Page 28: ...ive in this instance Non Windows browsers may require you to enter the complete IP address of the unit which you can always find by front panel navigation to Setup Network IP Settings Incoming Interne...

Page 29: ...ndard from the Audio En gineering Society specifies a 48kHz sample rate but Dante en coding can send at a 44 1kHz rate as well perhaps a more common rate in radio broadcast plants But with AES67 Enabl...

Page 30: ...SNMP submenu default Mode setting is Disabled which in hibits communication between the SOFIA 567 and the SNMP Manager Changing Mode to Read Only allows the SOFIA 567 to be inter rogated by the SNMP...

Page 31: ...mail under SMTP Settings You need to set up an actual email account the elements of which are just like setting up any con ventional email account Information to be entered here de pends on the provi...

Page 32: ...d with this Recipient proceed to the next A Save command is not necessary in this operation TIME SETUP Time and DST The onboard Real Time Clock will re ceive updates from Internet Time daily and has s...

Page 33: ...only trusted and authorized logged in users will be able to view those screens Once the password is saved no Web interface screen is accessi ble And on the front panel Now Playing will be the only sc...

Page 34: ...rofile The entire SOFIA 567 setup may be saved to your computer as a small text file The Hardware Profile includes user settings alarm notification entries SNMP options etc and is useful for restoring...

Page 35: ...fresh Hardware Profile as a firmware update may affect user settings If there is danger of compromising stored data the firmware update will include notes to that effect Updates are issued as small b...

Page 36: ...34...

Page 37: ...ion label has been removed or altered III TERMS OF WARRANTY Inovonics Inc products are warranted to be free from defects in materials and workmanship A Any discrepancies noted within THREE YEARS of th...

Page 38: ......

Reviews: