5 Parameter Table
- 35 -
■
Group F2: Vector Control
Para. No. Para. Name
Setting
Range
Unit
Default
Commission
F2-00
Speed loop proportional gain 1
1 to 100
N.A.
30
F2-01
Speed loop integral time 1
0.01 to 10.00
s
0.50
F2-02
Switchover frequency 1
0.00 to F2-05
Hz
5.00
F2-03
Speed loop proportional gain 2
1 to100
Hz
20
F2-04
Speed loop integral time 2
0.01 to10.00s
s
1.00
F2-06
Vector control slip gain
50 to 200
%
100
F2-07
Time constant of speed loop filter
0.000 to 1.000
s
0.050
F2-08
Vector control over-excitation
gain
0 to 200
N.A.
0
F2-09
Torque upper limit source in
speed control mode
0 to 7
N.A.
0
F2-10
Digital setting of torque upper
limit in speed control mode
0.0 to 200.0
%
150.0
F2-11
Selection of torque upper limit
reference setting channel in speed
control mode (regenerative)
0 to 8
N.A.
0
F2-12
Digital setting of torque upper
limit in speed control mode
(regenerative)
0.0 to 200.0
%
150.0
F2-13
Excitation adjustment
proportional gain
0 to 60000
N.A.
10
F2-14
Excitation adjustment integral
gain
0 to 60000
N.A.
10
F2-15
Torque adjustment proportional
gain
0 to 60000
N.A.
10
F2-16
Torque adjustment integral gain
0 to 60000
N.A.
10
F2-17
Speed loop property
00 to 11
N.A.
00
F2-18
Torque feedforward gain
20 to 100
N.A.
80
F2-21
Max. torque coefficient of field
weakening area
50 to 200
%
80
F2-22
Regenerative power limit
0.0: not
limited
0.1 to 200.0
%
0.0