Inoteska Anthrocite ST User And Installation Manual Download Page 9

 

 

SYSTEMS FOR VOICE AND DATA COMMUNICATION 

 

   

GSM

GSM

GSM

GSM    ////    ANALOG  DOOR 

ANALOG  DOOR 

ANALOG  DOOR 

ANALOG  DOOR PHONE STATION

PHONE STATION

PHONE STATION

PHONE STATION                    

                    

                    

                                    

                

                

                

    

    

specified  time  whether  next  pushbutton  is  pressed.  Image  can  be  transferred 
automatically if this function is activated for contact switch on evaluation.  
 

3.5 Additional functions 

 
Device senses one input contact which can be used for sensing the door opening or 
as alarm contact. 
 
It is possible to set various modes of relay number 2 control: 
 
- automatic switch on/off based on time settings (e.g. control of outdoor light) 
- always switch on when pushbutton is pressed  (e.g. for external camera) 
- always switch on when pushbutton in night mode is pressed  
- switch on when contact is switched on (e.g. for external alarm) 
- switch off when door is open 
- switch on when external gate is being closed 
 
Another additional function is switching between day and night modes and switching 
on the pushbuttons led illumination based on set time. Moreover, it is possible to set 
automatic  device  identification  after  turning  on  by  sending  its  serial  number  and 
mobile phone number to server, over some of above mentioned interfaces.  
 
GSM door entry phone station can transmit also various alarm messages, when: 
 
- door is open for long time 
- entrance without identification is  observed 
- incorrect identification, code is recorded  
- power supply drop-out 
- contact is switched on 
 
It  is  possible  to  set  which  alarm  types  have  to  be  signalized  and  then  the  interface 
type  for  each  alarm  type  alert.  To  send  alarm  alerts  by  SMS  or  calls  to  mobile 
numbers, separate table of called numbers is programmed.  

 

Optional firmware change - locally or remotely. 
Device diagnostics is also available. 

 

4. Configuration 

 
Device can be configured using configuration SW on PC: 
 
- locally: 
 

- by USB interface 

 
- remotely (central): 
 

-  over  USB  /  GSM  converter  by  data  connection  (M2M)  to  GSM  door  entry 

 

   phone station over mobile network 

 

-  over  Internet  network  using  TCP  /  IP  protocol  in  application  client-server, 

 

   where  GSM  door  entry  phone  station,  after  receiving  the  specified  number 

Summary of Contents for Anthrocite ST

Page 1: ...OR ANALOG DOOR ANALOG DOOR ANALOG DOOR PHONE STATION PHONE STATION PHONE STATION PHONE STATION GSM GSM GSM GSM ANALOG ANALOG ANALOG ANALOG DOOR ENTRY DOOR ENTRY DOOR ENTRY DOOR ENTRY PHONE PHONE PHONE...

Page 2: ...Table of analogue line parameters 5 5 Table of radio parameters 5 6 Table of RFID parameters 5 7 Table of camera parameters 5 8 Table of pushbutton codes 5 9 Table of numbers for 16 pushbuttons day m...

Page 3: ...rmware upgrade 10 Installation and setting up 11 Diagnostics 12 Technical parameters 12 1 Electrical parameters 12 2 Mechanical parameters 13 Operating environment 14 HW configuration and ordering 15...

Page 4: ...by calling from GSM door entry station to mobile phone fixed line or PbX call can be operated via GSM or analog line for calling through GSM GSM there is possibility of two step dial with dtmf dial w...

Page 5: ...SYSTEMS FOR VOICE AND DATA COMMUNICATION GSM GSM GSM GSM ANALOG DOOR ANALOG DOOR ANALOG DOOR ANALOG DOOR PHONE STATION PHONE STATION PHONE STATION PHONE STATION...

Page 6: ...tless Mifare cards reader automatic PCB heating when installed in cold environment radio in band 433 or 868 MHz external radio 10BT Ethernet converter for transfer of images attendance data or remotel...

Page 7: ...Each pushbutton press is signalized by acoustic signal For analog line the call release can not be reliably evaluated and therefore the call is ended either if preset max time expires or door is open...

Page 8: ...1 attendance arrival 2 interruption departure 3 interruption arrival 4 business departure 5 business arrival 6 doctor departure 7 doctor arrival or other customer codes total number of types is max 1...

Page 9: ...the pushbuttons led illumination based on set time Moreover it is possible to set automatic device identification after turning on by sending its serial number and mobile phone number to server over s...

Page 10: ...remote upgrade firmware via GSM network is unsuccessful only locally way by USB after turn off is able Configuration SW uses graphic mode Configurations data can be saved to PC Configuration SW contai...

Page 11: ...ation serial number production date device type hardware configuration radio band 433 or 868 MHz 5 2 Table of basic configuration 0 waiting time period for between individual presses of pushbuttons 10...

Page 12: ...fixed setting if not setting is by switching time 10 relay 2 switch on time hour minute 12 relay 2 switch off time hour minute 14 led pushbuttons turn on time hour minute 16 led pushbuttons turn off t...

Page 13: ...value 0 7 3 data baud rate value 0 13 35kbps 100kbps step 5kbps 4 radio output power value 0 7 1dB 20dB step 3dB 5 6 Table of RFID parameters 0 contactless card reader mode only ISO 14443A available...

Page 14: ...same as for day mode 5 11 Table of calling groups day mode 1 max 3 numbers one number max 14 digits number can also represent number of overflow group 2 parameters for each number 3 two step dial for...

Page 15: ...5535 5 17 Table of alarm alerts 1 alarm type 0 door opened for long time 1 entrance without identification 2 incorrect identification code 3 power supply drop out 4 contact switched on 5 SIM is remove...

Page 16: ...e parameter for example 2 8 4 set group 4 for pushbutton 8 in night mode FUNC3 change of numbers of group day mode 3 group number tel number parameter tel number parameter max 3 note tel number can be...

Page 17: ...C17 radio reset 17 FUNC18 rfid reset 18 FUNC19 set night mode 19 FUNC20 set day mode 20 7 Programming of contactless Mifare RFID cards Contactless cards can be programmed to device in programming mode...

Page 18: ...er option how to set the registration numbers or parameters after first programming of cards is to edit this data using configuration software in the same order as individual cards were scanned This p...

Page 19: ...SYSTEMS FOR VOICE AND DATA COMMUNICATION GSM GSM GSM GSM ANALOG DOOR ANALOG DOOR ANALOG DOOR ANALOG DOOR PHONE STATION PHONE STATION PHONE STATION PHONE STATION 8 Configuration software...

Page 20: ...anged In this state it is not possible to configure the device only after time is overflow remotely central over USB GSM converter by data connection M2M to GSM door entry phone station over mobile ne...

Page 21: ...ctrostatic discharge 2 After mechanical mounting of unit connect the cables power supply 12V DC relay contacts contact sensors expander box with 12 pushbuttons Before connecting the power supply as we...

Page 22: ...entre after its turning on power supply connection by sending its serial number and mobile phone number to server over pre set interface Device enables the diagnostics that means via USB interface to...

Page 23: ...quency detect bandwidth 2 2 DTMF detect response time 40ms DTMF pause length detected 30ms RFID 13 56MHz HF RFID reader ISO 14443A and B in this firmware only 14443A output power up to 500mW Radio fre...

Page 24: ...ns The product was shop checked The producer guarantees that this product will keep the features described in these operating instructions in the course of guarantee provided that the user will be han...

Page 25: ...3 or 868 MHz It uses TCP IP protocol in application client server With another firmware it can also be used as radio repeater To process attendance data and images from camera external application sof...

Page 26: ...ation door entry phone station radio parameters have to be same as in door entry phone station Firmware can to be changed by using TFTP protocol After turn on the device bootloader is running short ti...

Page 27: ...has to be set as in GSM door entry station Remote radio control unit is powered by internal 3V LION battery 17 1 Technical parameters Battery 3V CR2032 Radio 240 930 MHz FSK GFSK and OOK modulation m...

Page 28: ...erruption arrival 4 business departure 5 business arrival 6 doctor departure 7 doctor arrival Function attendance type and employee registration number is transmitted after pressing the pushbutton Not...