SYSTEMS FOR VOICE AND DATA COMMUNICATION 

 

   

GSM

GSM

GSM

GSM    ////    ANALOG  DOOR 

ANALOG  DOOR 

ANALOG  DOOR 

ANALOG  DOOR PHONE STATION

PHONE STATION

PHONE STATION

PHONE STATION                    

                    

                    

                                    

                

                

                

    

    

 
Device  enables  gate  remote  control  (car  entry)  using  relay1,  relay2  and  contact 
sensor.  In  this  mode,  relay1  opens  the  gate  and  relay2  closes  the  gate.  There  are 
two  ways  of  control.  It  is  possible  to  open  and  close  the  gate  (switch  on  relay1  or 
relay2)  using  radio  remote  control  in  band  433  or  868  MHz  with  4  programmable 
pushbuttons  (if  GSM  door  entry  phone  station  is  embedded  with  radio  interface). 
Another option is to open the gate by calling from preset mobile phone. Gate can be 
closed (relay2 is switched on) after connection of external infrared sensor to device 
sensor which is used to detect the car passing through the gate. Gate can be closed 
automatically also when radio remote control is used. 

 

 
3.3 Attendance evidence 

 
Device  can  be  also  used  as  attendance  system.  It  is  possible  to  set  the  codes, 
contactless cards or mobile phones whose attendance must be recorded. Then, after 
identification, system waits for pressing the appropriate attendance type pushbutton. 
Pushbuttons  have  multiple  functions.  Its  meaning  depends  on  the  state  when  the 
pushbutton is pressed. 
 
For attendance evidence, following meaning of pushbuttons can be programmed: 
   

0 - attendance departure 

  

1 - attendance arrival 

   

2 - interruption departure 

   

3 - interruption arrival 

   

4 - business departure 

   

5 - business arrival 

   

6 - doctor departure 

   

7 - doctor arrival 

or other customer codes (total number of types is max. 12). 
 
Only after pressing the pushbutton, if it is programmed as arrival, the particular relay 
is  switched  on  and  door  is  opened.  Each  code,  contactless  card  and  mobile  phone 
number  has  the  employee  registration  number  set.  This  number  together  with 
attendance  type,  date  and  time,  is  sent  via  radio  interface  and  radio  /  Ethernet 
converter  to  server  where  the  data  is  saved  and  processed.  Resulting  from  this, 
attendance evidence for one employee can be carried out in several ways.  
Special application software on server is necessary for function of receive and save 
the attendance data. Attendance evidence and door opening can be performed also 
using the radio remote control with 4 programmable pushbuttons of attendance type. 
It  is  the  most  speed  way.  The  door  is  opened  and no  next  pushbuttons  need  to  be 
pressed. 

 

3.4 Persons control 

 
If  device  is  equipped  with  integrated  color  camera,  then  it  is  possible  to  control  the 
visitors at the door entrance by sending the static images in JPEG format over radio 
interface  and  external  radio/Ethernet  converter  to  server.  To  display  the  images  on 
PC  or  mobile  phone,  special  application  software  must  be  used.  After  pressing  the 
pushbutton,  illumination  leds  are  activated  and  image  transfer  starts.  Transfer  is 
stopped  if  person  starts  to  enter  the  code.  Voice  call  is  delayed,  device  waits  the 

Summary of Contents for Anthrocite ST

Page 1: ...OR ANALOG DOOR ANALOG DOOR ANALOG DOOR PHONE STATION PHONE STATION PHONE STATION PHONE STATION GSM GSM GSM GSM ANALOG ANALOG ANALOG ANALOG DOOR ENTRY DOOR ENTRY DOOR ENTRY DOOR ENTRY PHONE PHONE PHONE...

Page 2: ...Table of analogue line parameters 5 5 Table of radio parameters 5 6 Table of RFID parameters 5 7 Table of camera parameters 5 8 Table of pushbutton codes 5 9 Table of numbers for 16 pushbuttons day m...

Page 3: ...rmware upgrade 10 Installation and setting up 11 Diagnostics 12 Technical parameters 12 1 Electrical parameters 12 2 Mechanical parameters 13 Operating environment 14 HW configuration and ordering 15...

Page 4: ...by calling from GSM door entry station to mobile phone fixed line or PbX call can be operated via GSM or analog line for calling through GSM GSM there is possibility of two step dial with dtmf dial w...

Page 5: ...SYSTEMS FOR VOICE AND DATA COMMUNICATION GSM GSM GSM GSM ANALOG DOOR ANALOG DOOR ANALOG DOOR ANALOG DOOR PHONE STATION PHONE STATION PHONE STATION PHONE STATION...

Page 6: ...tless Mifare cards reader automatic PCB heating when installed in cold environment radio in band 433 or 868 MHz external radio 10BT Ethernet converter for transfer of images attendance data or remotel...

Page 7: ...Each pushbutton press is signalized by acoustic signal For analog line the call release can not be reliably evaluated and therefore the call is ended either if preset max time expires or door is open...

Page 8: ...1 attendance arrival 2 interruption departure 3 interruption arrival 4 business departure 5 business arrival 6 doctor departure 7 doctor arrival or other customer codes total number of types is max 1...

Page 9: ...the pushbuttons led illumination based on set time Moreover it is possible to set automatic device identification after turning on by sending its serial number and mobile phone number to server over s...

Page 10: ...remote upgrade firmware via GSM network is unsuccessful only locally way by USB after turn off is able Configuration SW uses graphic mode Configurations data can be saved to PC Configuration SW contai...

Page 11: ...ation serial number production date device type hardware configuration radio band 433 or 868 MHz 5 2 Table of basic configuration 0 waiting time period for between individual presses of pushbuttons 10...

Page 12: ...fixed setting if not setting is by switching time 10 relay 2 switch on time hour minute 12 relay 2 switch off time hour minute 14 led pushbuttons turn on time hour minute 16 led pushbuttons turn off t...

Page 13: ...value 0 7 3 data baud rate value 0 13 35kbps 100kbps step 5kbps 4 radio output power value 0 7 1dB 20dB step 3dB 5 6 Table of RFID parameters 0 contactless card reader mode only ISO 14443A available...

Page 14: ...same as for day mode 5 11 Table of calling groups day mode 1 max 3 numbers one number max 14 digits number can also represent number of overflow group 2 parameters for each number 3 two step dial for...

Page 15: ...5535 5 17 Table of alarm alerts 1 alarm type 0 door opened for long time 1 entrance without identification 2 incorrect identification code 3 power supply drop out 4 contact switched on 5 SIM is remove...

Page 16: ...e parameter for example 2 8 4 set group 4 for pushbutton 8 in night mode FUNC3 change of numbers of group day mode 3 group number tel number parameter tel number parameter max 3 note tel number can be...

Page 17: ...C17 radio reset 17 FUNC18 rfid reset 18 FUNC19 set night mode 19 FUNC20 set day mode 20 7 Programming of contactless Mifare RFID cards Contactless cards can be programmed to device in programming mode...

Page 18: ...er option how to set the registration numbers or parameters after first programming of cards is to edit this data using configuration software in the same order as individual cards were scanned This p...

Page 19: ...SYSTEMS FOR VOICE AND DATA COMMUNICATION GSM GSM GSM GSM ANALOG DOOR ANALOG DOOR ANALOG DOOR ANALOG DOOR PHONE STATION PHONE STATION PHONE STATION PHONE STATION 8 Configuration software...

Page 20: ...anged In this state it is not possible to configure the device only after time is overflow remotely central over USB GSM converter by data connection M2M to GSM door entry phone station over mobile ne...

Page 21: ...ctrostatic discharge 2 After mechanical mounting of unit connect the cables power supply 12V DC relay contacts contact sensors expander box with 12 pushbuttons Before connecting the power supply as we...

Page 22: ...entre after its turning on power supply connection by sending its serial number and mobile phone number to server over pre set interface Device enables the diagnostics that means via USB interface to...

Page 23: ...quency detect bandwidth 2 2 DTMF detect response time 40ms DTMF pause length detected 30ms RFID 13 56MHz HF RFID reader ISO 14443A and B in this firmware only 14443A output power up to 500mW Radio fre...

Page 24: ...ns The product was shop checked The producer guarantees that this product will keep the features described in these operating instructions in the course of guarantee provided that the user will be han...

Page 25: ...3 or 868 MHz It uses TCP IP protocol in application client server With another firmware it can also be used as radio repeater To process attendance data and images from camera external application sof...

Page 26: ...ation door entry phone station radio parameters have to be same as in door entry phone station Firmware can to be changed by using TFTP protocol After turn on the device bootloader is running short ti...

Page 27: ...has to be set as in GSM door entry station Remote radio control unit is powered by internal 3V LION battery 17 1 Technical parameters Battery 3V CR2032 Radio 240 930 MHz FSK GFSK and OOK modulation m...

Page 28: ...erruption arrival 4 business departure 5 business arrival 6 doctor departure 7 doctor arrival Function attendance type and employee registration number is transmitted after pressing the pushbutton Not...