![Inoteska Anthrocite ST User And Installation Manual Download Page 16](http://html1.mh-extra.com/html/inoteska/anthrocite-st/anthrocite-st_user-and-installation-manual_2064555016.webp)
SYSTEMS FOR VOICE AND DATA COMMUNICATION
GSM
GSM
GSM
GSM //// ANALOG DOOR
ANALOG DOOR
ANALOG DOOR
ANALOG DOOR PHONE STATION
PHONE STATION
PHONE STATION
PHONE STATION
6. Device configuration over SMS
Each SMS must begin with character
"/"
. Then
number of function
and
","
. All
parameters, values are separated by
","
.
Other characters which are used:
"
#
" ,"
*
",
"
>
"
and
"
:
"
. Value and parameters, using SMS functions, correspond to the
particular table in configuration data structure. Parameter can be one of these
parameters.
Following functions are available by SMS:
FUNC1 -
change of pushbutton number - day mode
/1, pushbutton number (1..16), tel. number or #group number, *parameters
note: parameters = attendance type value
","
parameter
for example:
/1,16,0903123456,*01
(set number 0903123456 for pushbutton 16 in day mode, attendance
departure, switch on relay 1)
FUNC2 -
change of pushbutton number - night mode
/2, pushbutton number (1..16), tel. number or #group number, *parameters
note: parameters = attendance type value
","
parameter
for example:
/2,8,#4
(set group 4 for pushbutton 8 in night mode)
FUNC3
- change of numbers of group - day mode
/3, group number, tel. number, *parameter, tel. number, *parameter,...(max. 3)
note: tel. number can be also # and number of overflow group
for example:
/3,4,0911987654,201,*4,
(set two numbers for group 4 in day mode:
0911987654 and 201 - call over analog line)
FUNC4
- change of numbers of group - night mode
/4, group number, tel. number, *parameter, tel. number, *parameter,...(max. 3)
note: tel. number can be also #number of overflow group
FUNC5
- change of code of pushbuttons
/5, old code, new code (max. 5), *parameter, #employee registration number
note: if new one is blank -> only old one is deleted
FUNC6
- setting of new code of pushbuttons
/6, code (max. 5), *parameter, #employee registration number
FUNC7
- change of CLIP (in table of identification - call from GSM for relay switch on)
/7, old clip, new clip, *parameter, #employee registration number
note: if new clip is blank -> only old one is deleted
FUNC8
- setting of new CLIP (in table of identification - call from GSM for relay
switch on)
/8, clip, *parameter, #employee registration number
FUNC9
- CLIP for device configuration
/9, old clip, new clip, *parameter