SCAMAX
®
2600/4000
Tech. Manual 06/2002
T-47
Ï
Ð
ProcessorReset
ª
Initiates endorser reset.
Ï
Ð
TestPrint
ª
Initiates test print. (insert
paper under endorser!)
Ï
Ð
Date : DD.MM.YY
ª
Date : 01.01.00
Displays current date.
Ï
Ð
Time : HH.MM:SS
ª
Time : 13.19:24
Displays current time.
Ð
3.9 Power Supply
3.9.1 Mains Power Switch Unit
The mains power switch unit contains:
A ceramic housing with two fuses T 3.15A/250V,
∅
5X20mm, suitable for both 230V and 115V mains
voltage. The ceramic housing has several electrical contacts and can be inserted in two positions. Each
position displays either 230V or 115V.
The ceramic housing can be removed by using a screwdriver.
a LC system filter
a mains switch
a connection for the power cord
an elastic plastic covering that guards against touching live parts. This is particularly important when
adjusting the back camera.
Changing mains voltage prior to first time use and changing fuses is described in the operating
instructions.