20
5. MAINTENANCE
Disconnect the electrical
connection of the
appliance
immediately
before
beginning
maintenance or cleaning activities.
Before the first use, the electrical connection of the
appliance must be disconnected and it must be
cleaned with warm soapy water.
Water must definitely not be sprayed or spilled on
the appliance.
Clean the appliance at the end of each working day
with a piece of cloth soaked with warm soapy water
and with a disinfectant that will not harm nutrition
products (especially the areas in contact with
meat).
Pins and tray plate contacted by the meat may be
washed in the dishwasher.
Do not use materials that can scratch the surface
such as detergent with abrasive ingredients, wire
brushes, etc. when cleaning the surface of the
appliance.
If the appliance will not be used for a long period
of time, the surface should be coated with a thin
layer of Vaseline.
Notify the authorized service if the appliance is
considered in a dangerous situation. Do not allow
incompetent persons to interfere with the
appliance.
Contact manufacturer when the maintenance
period of the appliance has expired and/or when
the appliance has a fault.
WARNING:
Do not clean the appliance with
9. TRANSFORMATION FOR DIFFERENT
GAS TYPES
Refer to table “T1” for adaptation to different gas
types.
Choose the injector suitable for the gas type and pressure
to be used from table “T1” and install it to the housing of
the removed injector.
Label for the new gas type shall be affixed by removingthe
current label after adapting the appliance to a different gas
type than the gas type set by the manufacturer.
9.1 Replacement of Injector
Select suitable injector from table T1.
Remove the rear plate of the appliance.
(1) Face the radiant. (2) Remove the pin on the
radiant. (3) Remove injector from the radiant. (4)
Replace with new injector and install the new
injector to the same housing. (5) Install the pin as
you have removed it. (6) Gas type transformation is
complete.
Injector diameters are printed on the injectors.