66
Excess foam may reveal when
the detergent is used excessively.
If
cooking
shall
not
be
performed after flushing, door should
be left open for a while.
No intervention should be made
to the device during flushing, and end
of flushing operation should be waited.
21. MAINTENANCE
Device has no parts to be repaired or
replaced by the user.
In case of any dangerous situation in
the device, initially disconnect the
electricity, then inform the authorized
service. Do not allow unauthorized
persons to make intervention on the
device.
22. POSSIBLE PROBLEMS AND
SOLUTIONS
Device does not operate if the oven
door is completely closed in cooking
position. Pay attention to exact fit of
the door lever into its place.
Device
operation
shall
be
interrupted if the oven door is opened
while the device operates. It continues
operating when the door is closed.
In case of any device failure, related
failure message shall be seen on the
screen. You can find related failure
code explanation in the list below.
Consider solution recommendations from the table below depending on
the failure notification.
ERROR
CODE
ERROR MESSAGE
POSSIBLE PROBLEM AND SOLUTION
RECOMMENDATION
E108
Phase-Neutral connected false Phase-Neutral electricity connection of electricity grid
is faulty and grid power interruption has occurred.
E109
Fuse blown
Over current protection element of electronic control
unit should be replaced.
Please contact with the authorized service unit!
E113
Electrical panel is overheated.
Failure shall be given if the ambient temperature of
electronic card unit is over 60°C. Fan filter should be
cleaned; please contact with the authorized service
unit if failure continues after the cleaning operation!
E203
Condensation tank cannot be
cooled down.
Grid water connection is closed or inadequate grid
water pressure. After controlling the grid water
connection, observe that the failure is eliminated by
selecting "Delete Failure and Continue" symbol.
Otherwise, please contact with the authorized service
unit!
E209
Boiler filling period exceeded
Grid water connection is closed or inadequate grid
water pressure. 5 minutes after controlling the grid
water connection, observe that the failure is
eliminated by selecting "Delete Failure and Continue"
symbol.
Summary of Contents for inosmart FBG10T
Page 4: ...4 1 PİKTOGRAM AÇIKLAMALARI ...
Page 10: ...10 5 ÜRÜN GÖRÜNÜŞLERİ FBG 40T ...
Page 11: ...11 FBG 20T ...
Page 12: ...12 FBG 10T ...
Page 13: ...13 6 İŞLEV PARÇALARI Fırının bölümleri ...
Page 18: ...18 8 GENEL GÖRÜNÜM ...
Page 22: ...22 10 PİŞİRME MODLARI 1 KOMBİ MOD 2 TURBO MOD 3 BUHAR MODU 4 AYARLANABİLİR BUHAR MODU ...
Page 24: ...24 ...
Page 43: ...43 5 PRODUCT VIEWS FBG 40T ...
Page 44: ...44 FBG 20T ...
Page 45: ...45 FBG 10T ...
Page 50: ...50 8 GENERAL VIEW ...
Page 54: ...54 10 COOKING MODES 1 COMBI MODE 2 TURBO MODE 3 STEAM MODE 4 ADJUSTABLE STEAM MODE ...