10 CONNECTION TO POWER SOURCE
10.1 Electricity connection
WARNING:
All machines with conveyors will be fed with 45-50
°
C hot water inlet and 400V 50Hz. A.C. electricity.
Except the detailed requests provided with the purchase order.
a
)
M
a
k
i
n
e
n
i
n
Make sure that the voltage and frequency values of the circuit is the
same as the values indicated on the machine before connection.
b)
Electricity connection of the machine should be in compliance
with domestic installation regulations (multipolar automatic circuit
breaker or thermic magnetic switch). Distance between the contacts
of this circuit breaker of switch should at least be 3 mm. Switch (or
automatic circuit breaker) should be wall-mounted somewhere
easily accessible, not on the machine (ground clearance should be
between 0,6-1,7 m).
c)
Make sure the electricity is turned off before connecting the
machine to the power source.
d)
Connect the power source cable to the machine as shown in the
image:
d1)
Remove the screw on the panel with the help of a fillister head
screw driver.
d2)
Lift the stainless lid near the panel.
d3)
Lift the PVC lid on the busbar box and connect phase cables to
busbars marked as L1, L2, and L3.
d4)
Tightly close the PVC lid on the busbar box.
d5)
Check the tightness of the cable connections considering they
may have slacked during transportation.
d6)
Reclose the stainless lid on the panel.
d7)
Use a fillister head screw driver to close the panel lid.
WARNING: Switch and power source cable connections should
be as shown in Image 6.
Installation and electricity connection of the device should be
done according to the standards by authorized personnel.
4x16+10mm
2
sized NYY cable should be used for electricity
connection.
Voltage tolerance should not exceed ± 10%.
Device should be connected to the feeding line through 3x63A
circuit breaker.
Device should certainly be connected to a grounding line. DIN
VDE 0100 article 540 should be considered for this. Grounding
screw is shown as "
" on the machine.