Document Name : OIM V 1.0 Page 3 of 7
3
User List :-
1) To access the User List Press ‘SET’ key.
2) Press ‘UP / DOWN’ Key to change the value.
3) Press ‘SET’ Key to store the data & move on to next parameter.
Auto
Reset
Time
5.0
Auto Reset Time :-
It will appears only if Selected counter mode is Auto Reset or
TPR. User can set Auto Reset time form 0.1Sec to 99.9Sec. via SET & RST Key.
Set
Batch
5
Set Batch :-
This parameter will appears only if Op2 is selected as Batch Mode.
After achieving Batch set point output 2 will be turned On (Range from 1 to 9999).
Parameter
Lower
Display
Upper
Display
Description
Default
5
Set
Count
In RUN mode, Press ‘Set’ key to set count value. 'S.CNT' will be displayed on lower
display & last stored/default value of 'set count' will be displayed on upper display.
User can change this value by using Up/Down/Shift key. Press ‘'Set' key to store
Set value & move to next parameter.
i
Scale
Factor
0001
Scale Factor :- User can set the value of scale factor. The last stored value of scale
with decimal position will be display. Use Up / Down / Shift Key to change scale
factor value. In run mode, on receiving Count Pulse the counter will Increment or
Decrement count value by the scale factor & Count Direction provided by the user.
Select
Decimal
Point
0000.
Select Decimal Point :-
User can set position of decimal point for scale factor.
Position of decimal point can be shifted by using the shift key.
Memory
Backup
Memory Backup :-
This parameter allows the user to Enable or Disable Memory
Backup function.
Disable :- If selected; At the time of Power Failure Running Count will not be Stored
in Memory. Counter will be Reset at next power On.
Enable :-
If selected; At the time of Power Failure Running Count value is Stored in
Memory.
Enable
Upper
Display
Parameter
Description
Default
Lower
Display
Front
Reset
Enable
Enable
Front Reset
:-
This feature prevents un-authorized attempt to Reset the Counter during Run mode.
This parameter allows the user to Enable or Disable front Reset function.
Disable :-
If selected;
Down key. Only Remote Reset at back terminal is allowed.
The Counter can not be reset through front panel by pressing
Enable :-
If selected;
Down key
The Counter can be reset through front panel by pressing
Over
Run
Mode
Enable :- If selected;
Only the Output remains latched thereafter until count is reset.
Counting continues after the set value of count is reached.
Disable :- If selected; C
o/p & count remains latched thereafter until count is reset.
ounting stops after the set value of count is reached. The
Over Run Mode :-
This parameter occurs only if Latch Output mode with UP
Counting Selected.
Resolution
0000.
Resolution :-
This parameter doesn't appear if the Selected Decimal position for
scale is at 4th position (0000.). User can set screen resolution for RUN Mode.
Note: Max screen Resolution is equal to resolution for scale factor.
Auxiliary
Output 2
Function
OFF:
If selected , OP2 will be completely OFF.
AUXILIARY:
If selected , OP2 can be used as Auxiliary contact. Both the relay
output will ON/OFF together as per the ON/OFF Delay.
INVERT:
If selected , OP2 logic will be inverse of OP1. Both the relay output will
ON/OFF visa-versa as per the ON/OFF Delay.
BATCH:
If selected , Output2 used as a Batch mod. When Batch count EQUAL
S.Bch output2 will on & the output of second relay will remain ON until user press
the reset key for 3second when Batch count displayed.