Document Name : OIM V 1.0 Page 3 of 7

3

User List :-

1) To access the User List Press  ‘SET’ key.
2) Press ‘UP / DOWN’ Key to change the value. 
3) Press ‘SET’ Key to store the data & move on to next parameter.

Auto

Reset

Time

5.0

Auto Reset Time :- 

It will appears only if Selected counter mode is Auto Reset or 

TPR. User can set Auto Reset time form 0.1Sec to 99.9Sec. via SET & RST Key.

Set

Batch

5

Set Batch :-

 

This parameter will appears only if Op2 is selected as Batch Mode.

After achieving Batch set point output 2 will be turned On (Range from 1 to 9999).

Parameter

Lower

Display

Upper

Display

Description

Default

5

Set

Count

In RUN mode, Press ‘Set’ key to set count value. 'S.CNT' will be displayed on lower 
display & last stored/default value of 'set count' will be displayed on upper display. 
User  can  change  this  value  by  using  Up/Down/Shift  key.  Press  ‘'Set'  key  to  store 
Set value & move to next parameter.

i

Scale

Factor

0001

Scale Factor :- User can set the value of scale factor. The last stored value of scale 
with  decimal  position  will  be  display.  Use  Up  /  Down  /  Shift  Key  to  change  scale 
factor  value.  In  run  mode,  on  receiving  Count  Pulse  the  counter  will  Increment  or   
Decrement count value by the scale factor & Count Direction provided by the user.

Select

Decimal

Point

0000.

Select  Decimal  Point  :-

 

User  can  set  position  of  decimal  point  for  scale  factor. 

Position of decimal point can be shifted by using the shift key.

Memory

Backup

Memory  Backup  :-

 

This  parameter  allows  the  user  to  Enable  or  Disable  Memory 

Backup function.

Disable :- If selected; At the time of Power Failure Running Count will not be Stored 
in Memory. Counter will be Reset at next power On.

 

Enable :-

 

If selected; At the time of Power Failure Running Count value is Stored in 

Memory.

Enable

Upper

Display

Parameter

Description

Default

Lower

Display

Front
Reset

Enable

Enable

Front Reset 

:-

 

This feature prevents un-authorized attempt to Reset the Counter during Run mode.

This parameter allows the user to Enable or Disable front Reset function. 

Disable :-

 

If selected; 

Down key. Only Remote Reset at back terminal is allowed.

The Counter can not be reset through front panel by pressing 

Enable  :-

 

If  selected; 

Down key

The  Counter  can    be  reset  through  front  panel  by  pressing 

Over

Run

Mode

Enable  :-  If  selected; 
Only the Output remains latched thereafter until count is reset.

Counting  continues  after  the  set  value  of  count  is  reached. 

Disable  :-  If  selected;  C
o/p & count remains latched thereafter until count is reset.

ounting  stops  after  the  set  value  of  count  is  reached.  The 

Over  Run  Mode  :-

 

This  parameter  occurs  only  if  Latch  Output  mode  with  UP 

Counting Selected.

Resolution

0000.

Resolution  :-

 

This  parameter  doesn't  appear  if  the  Selected  Decimal    position  for 

scale is at 4th position (0000.). User can set screen resolution for RUN Mode.
Note: Max screen Resolution is equal to resolution for scale factor.

Auxiliary

Output 2
Function

OFF:

 

If selected , OP2 will be completely OFF.

 

AUXILIARY:

 

If  selected  ,  OP2  can  be  used  as  Auxiliary  contact.  Both  the  relay 

output will ON/OFF together as per the ON/OFF Delay.

INVERT:

 

If  selected  ,  OP2  logic  will  be  inverse  of  OP1.  Both  the  relay  output  will 

ON/OFF visa-versa as per the ON/OFF Delay.

BATCH:

 

If  selected  ,  Output2  used  as  a  Batch  mod.  When  Batch  count  EQUAL 

S.Bch output2 will on & the output of second relay will remain ON until user press 
the reset key for 3second when Batch count displayed. 

Summary of Contents for KTC-44

Page 1: ...urrounding the Controller must not exceed the maximum specified limits v The Controller in its installed state must be protected against excessive electrostatic or electromagnetic interferences ELECTR...

Page 2: ...ery Low If selected count input frequency is 3Hz Low If selected count input frequency is 30Hz Medium If selected count input frequency is 100Hz High If selected count input frequency is 1000Hz Very H...

Page 3: ...d in Memory Counter will be Reset at next power On Enable If selected At the time of Power Failure Running Count value is Stored in Memory Enable Upper Display Parameter Description Default Lower Disp...

Page 4: ...Min Resolution 1 Min 9999 Sec Range 2 Min Min Min Min Min Hrs Sec Hrs Sec Min Hrs Sec Hrs Sec Hrs Sec Hrs Sec TIMER RANGE RESOLUTION Range 99 99 Sec Resolution 0 01 Sec Range 999 9 Sec Resolution 0 1...

Page 5: ...e at back terminal from external Input Remote Edge Negative Trigger Start If Selected Timer starts counting only when it detects low to high pulse at back terminal from external Input Remote Edge Trig...

Page 6: ...put can be used as a Gate input i Disable Memory Backup Memory Backup This parameter allows the user to Enable or Disable memory backup function Enable Memory backup for run time value Disable No memo...

Page 7: ...ec Hrs Min Sec Set Time Set EOC Time Running Time Set Time Number of cycles Total Time b For CY3 0 01 999 9 5 0 FORWARD TIME Prompted only if selected mode is CY3 Cyclic with Hold Sets the FORWARD tim...

Reviews: