Document Name : OIM V 1.0 Page 2 of 7

1) To Enter in this mode Press & Hold ‘SET & UP’ key for 5 sec. at Power On.  ‘CNFG’ & ‘V.6.0.0'  Message will display for 5 Sec.   
2) Press ‘SET’ Key to move on to next parameter. 
3) Press ‘UP / DOWN / SHIFT’ Key to scroll / change parameter options.

Mode Selection :-

Programming

Upper

 Display

KTC Mode :-

 

Key Board Timer / Counter Mode Selection.

Counter :-

 

If Selected, Controller will work as Counter.

Ref. Page No. 2 to 4
Timer :-

 

If Selected, Controller will work as Timer.

Ref. Page No. 4 to 7

Counter

Mode

Selection

Parameter

Description

Default

Lower

Display

Lock  Code  :-

 

Set  this  parameter  to  15(Default  Lock  Code)  to  view  or  edit  Selected 

Mode. User has choice to set different Lock Code from User Lock Code Parameter. 

Lock
Code

0

User  Lock  Code  :-

 

Default  User  Lock  Code  is  15.  User  has  choice  to  set  its  own 

Lock Code in between 1 to 9999, This parameter is to prevent unauthorized access 
of Mode Selection.  

User

Lock
Code

15

Programming as Counter Mode

1) To Enter in this mode Press & Hold ‘SET’ key for 5 sec. at Power On.  ‘CNFG’ & ‘V.6.0.0'  Message will display for 5 Sec.   
2) Press ‘SET’ Key to move on to next parameter. 
3) Press ‘UP / DOWN / SHIFT’ Key to scroll / change parameter options.

Configuration List :-

i

Count 

Direction

Down

Count Direction :- This parameter allows user to set count direction in run mode as 
follows
Up  Count  :-  If  selected  counting  starts  from  0000  up  to  set  count  in  ascending 
order.
Down  Count  :-  If  selected;  counting  starts  from  set  count    to  0000  in  descending 
order.

Input 

Frequency

Output 1
Function

Medium 

On

Delay 

Input  Frequency  :-  User  can  select  the  frequency  of  count  pulse  at  the  input 
terminal. This feature is useful in avoiding noise signal.  

Very Low :- If selected count input frequency is 3Hz.

Low :- If selected count input frequency is 30Hz.

Medium :- If selected count input frequency is 100Hz.

High :- If selected count input frequency is 1000Hz.

Very High :- If selected count input frequency is 2500Hz.

On  Delay  :- 
completion of count; Output 1 change its state(ON) & remain in that state until user

 

press RESET or next cycle begins(in auto reset mode & TPR mode).

During  Counter  is  in  run  mode;  Output  1  still  remain  OFF.

  At 

the 

Off  Delay  (Interval)  :- 
At  the  completion  of  count;  Output  1  change  its  state(OFF)  &  remain  in  that  state 
until user press RESET or next cycle begins(in auto reset mode & TPR mode).

During  Counter  is  in  run  mode;  Output  1  get  energised(ON). 

DC

Count

Input 

Type

AC : If selected count input from 230V AC mains supply.  

DC : If selected count input from Proximity or Potential free contact.  

Count Input Type :- By this parameter lets the user select Input type for counting.

Upper

Display

Parameter

Description

Default

Lower

Display

Counter

Mode

Latch

Output

Mode

(LO)

Latch Output Mode :- If selected; W
O/Ps changes its state & remains in this state until reset key or rear reset pressed.

hen  actual counts reaches its set value ,Relay 

Auto  Reset  Output  Mode  :-  If  selected; 
the set value of count has been reached; it will remain in same position & wait for 
end  of  auto  reset  time.  On  completion  of  this  time,  counter  will  reset  i.e.  relay 
contact  positions  initialize  depending  on  'ON'  or  'OFF'  Delay  mode  selected 
&counter will start counting again.

When  relay  contacts  change  its  state  after 

TPR  Output  Mode  :-  If  selected; 
value of count has been reached; Relays will remain in this state for 'TPR' time. On 
completion  of  this  time,  relay  contact  positions  initialize  depending  on  'ON'  or 
'OFF' Delay mode selected. Unlike Auto reset mode, counting continues during the 
TPR time.

when  relay  contacts  change  its  state  after  the  set 

Summary of Contents for KTC-44

Page 1: ...urrounding the Controller must not exceed the maximum specified limits v The Controller in its installed state must be protected against excessive electrostatic or electromagnetic interferences ELECTR...

Page 2: ...ery Low If selected count input frequency is 3Hz Low If selected count input frequency is 30Hz Medium If selected count input frequency is 100Hz High If selected count input frequency is 1000Hz Very H...

Page 3: ...d in Memory Counter will be Reset at next power On Enable If selected At the time of Power Failure Running Count value is Stored in Memory Enable Upper Display Parameter Description Default Lower Disp...

Page 4: ...Min Resolution 1 Min 9999 Sec Range 2 Min Min Min Min Min Hrs Sec Hrs Sec Min Hrs Sec Hrs Sec Hrs Sec Hrs Sec TIMER RANGE RESOLUTION Range 99 99 Sec Resolution 0 01 Sec Range 999 9 Sec Resolution 0 1...

Page 5: ...e at back terminal from external Input Remote Edge Negative Trigger Start If Selected Timer starts counting only when it detects low to high pulse at back terminal from external Input Remote Edge Trig...

Page 6: ...put can be used as a Gate input i Disable Memory Backup Memory Backup This parameter allows the user to Enable or Disable memory backup function Enable Memory backup for run time value Disable No memo...

Page 7: ...ec Hrs Min Sec Set Time Set EOC Time Running Time Set Time Number of cycles Total Time b For CY3 0 01 999 9 5 0 FORWARD TIME Prompted only if selected mode is CY3 Cyclic with Hold Sets the FORWARD tim...

Reviews: