Document Name : OIM V 1.0 Page 2 of 7
1) To Enter in this mode Press & Hold ‘SET & UP’ key for 5 sec. at Power On. ‘CNFG’ & ‘V.6.0.0' Message will display for 5 Sec.
2) Press ‘SET’ Key to move on to next parameter.
3) Press ‘UP / DOWN / SHIFT’ Key to scroll / change parameter options.
Mode Selection :-
Programming
Upper
Display
KTC Mode :-
Key Board Timer / Counter Mode Selection.
Counter :-
If Selected, Controller will work as Counter.
Ref. Page No. 2 to 4
Timer :-
If Selected, Controller will work as Timer.
Ref. Page No. 4 to 7
Counter
Mode
Selection
Parameter
Description
Default
Lower
Display
Lock Code :-
Set this parameter to 15(Default Lock Code) to view or edit Selected
Mode. User has choice to set different Lock Code from User Lock Code Parameter.
Lock
Code
0
User Lock Code :-
Default User Lock Code is 15. User has choice to set its own
Lock Code in between 1 to 9999, This parameter is to prevent unauthorized access
of Mode Selection.
User
Lock
Code
15
Programming as Counter Mode
1) To Enter in this mode Press & Hold ‘SET’ key for 5 sec. at Power On. ‘CNFG’ & ‘V.6.0.0' Message will display for 5 Sec.
2) Press ‘SET’ Key to move on to next parameter.
3) Press ‘UP / DOWN / SHIFT’ Key to scroll / change parameter options.
Configuration List :-
i
Count
Direction
Down
Count Direction :- This parameter allows user to set count direction in run mode as
follows
Up Count :- If selected counting starts from 0000 up to set count in ascending
order.
Down Count :- If selected; counting starts from set count to 0000 in descending
order.
Input
Frequency
Output 1
Function
Medium
On
Delay
Input Frequency :- User can select the frequency of count pulse at the input
terminal. This feature is useful in avoiding noise signal.
Very Low :- If selected count input frequency is 3Hz.
Low :- If selected count input frequency is 30Hz.
Medium :- If selected count input frequency is 100Hz.
High :- If selected count input frequency is 1000Hz.
Very High :- If selected count input frequency is 2500Hz.
On Delay :-
completion of count; Output 1 change its state(ON) & remain in that state until user
press RESET or next cycle begins(in auto reset mode & TPR mode).
During Counter is in run mode; Output 1 still remain OFF.
At
the
Off Delay (Interval) :-
At the completion of count; Output 1 change its state(OFF) & remain in that state
until user press RESET or next cycle begins(in auto reset mode & TPR mode).
During Counter is in run mode; Output 1 get energised(ON).
DC
Count
Input
Type
AC : If selected count input from 230V AC mains supply.
DC : If selected count input from Proximity or Potential free contact.
Count Input Type :- By this parameter lets the user select Input type for counting.
Upper
Display
Parameter
Description
Default
Lower
Display
Counter
Mode
Latch
Output
Mode
(LO)
Latch Output Mode :- If selected; W
O/Ps changes its state & remains in this state until reset key or rear reset pressed.
hen actual counts reaches its set value ,Relay
Auto Reset Output Mode :- If selected;
the set value of count has been reached; it will remain in same position & wait for
end of auto reset time. On completion of this time, counter will reset i.e. relay
contact positions initialize depending on 'ON' or 'OFF' Delay mode selected
&counter will start counting again.
When relay contacts change its state after
TPR Output Mode :- If selected;
value of count has been reached; Relays will remain in this state for 'TPR' time. On
completion of this time, relay contact positions initialize depending on 'ON' or
'OFF' Delay mode selected. Unlike Auto reset mode, counting continues during the
TPR time.
when relay contacts change its state after the set