496332 Issue 1
21 of 22
LIM ### shunted
Restore branch
The following are software diagnostic messages which should appear in the
log very rarely. They all indicate that a fault has occurred, which has caused
the microprocessor to reset. The system will operate correctly following this
reset.
Fault watchdog
Fault software
Fault stack
Fault comm stop
Fault power/wdog
Fault stack top
The following messages are logged when the panel is powered up for the
first time, and in normal operation should never again appear in the log.
Fault checksum
(High security data has been corrupted. Defaults
have been loaded)
<SYSTEM RESET>
(The system has reset, and is running on default
parameters)
User Commands
ACCESS CODE SPECIFICATION
1 - Master manager code (manager number 1)
49 - Manager codes (manager numbers 2 to 50)
49 - Operator codes (operators 1 to 49)
1- Cleaner code
(operator number 0)
1 - Duress code
(operator 99 in log events memory)
1 - Engineer code
This can only be used with the system in Status
Day.
Any access code can be any mixture of numbers between 4 and 8 digits
The standard factory default codes are:-
Manager 1 code = 4567 followed by "ENTER"
Engineer code = 7890 followed by "ENTER"
All other codes are undefined.
9500
User Commands
Summary of Contents for 9500
Page 4: ...4 of 22 496332 Issue 1 Wiring Figure 2 Main PCB Layout Figure 3 Main PCB Connections 9500 ...
Page 12: ...12 of 22 496332 Issue 1 Engineering Program Commands 9500 ...
Page 13: ...496332 Issue 1 13 of 22 9500 Engineering Program Commands ...
Page 14: ...14 of 22 496332 Issue 1 Engineering Program Commands 9500 ...