496332 Issue 1
17 of 22
prevent any problems of high current being drawn which could damage the
control panel.
2. The Engineer Reset, Test Functions and Reports can be selected without
opening the control panel lid.
Refreshing The System
If the system requires all the programmed information to be deleted and
returned to the factory de-faults, it is possible to refresh the system in the
following way.
1.
Completely power down the control panel.
2.
Remove the RAM chip, which is located on the main PCB and is the
centre of the three large chips.
3.
Replace the chip and Power up the control panel. Reset the system and
continue to re-programme as required.
9500 LOG EVENTS
Access engineer
Tamp. panel keys
Excess key presses
Fault tel line
Telephone line fault (line missing)
Fault tel comm
Telephone communication failure
(e.g., no reply)
Fault mains
A.C. Power failure
Fault battery
Fault aux supply
Aux. 12v DC fuse blown
Fault all power
Total power failure
Engineer reset
Customer reset
Set proc started
Set procedure started
Walk test
System walk test
Viewed ENG log
Viewed engineers log
MGR 24-hr omit
Manager omitted 24-hour circuits
(list follows)
-R-tamper-panel-
Restore panel tamper
-R-tamper-bell-
Restore bell tamper
—R-tel-line—
Restore telephone line
-Mains- restored-
9500
Refreshing the System
Summary of Contents for 9500
Page 4: ...4 of 22 496332 Issue 1 Wiring Figure 2 Main PCB Layout Figure 3 Main PCB Connections 9500 ...
Page 12: ...12 of 22 496332 Issue 1 Engineering Program Commands 9500 ...
Page 13: ...496332 Issue 1 13 of 22 9500 Engineering Program Commands ...
Page 14: ...14 of 22 496332 Issue 1 Engineering Program Commands 9500 ...