Programming
Initial Start Up
Check that all LIM box tampers are closed. Make sure that the Bell and
Strobe is not connected to the main 9500 PCB. Link out any circuits that are
nnot used.
When powering up the panel for the first time:
1.
Close the control panel lid and connect the mains supply.
The display shows:
<SYSTEM RESET>
12:00 16 OCT 90
Alternating with:
12:00 16 OCT 90
Status : Alarm
2.
Key in 4567 + Enter.
The display shows:
Display
customer log?
3.
Press No.
The display shows:
<SYSTEM RESET>
12:00 16 OCT 90
Alternating with:
16 OCT 12:00:00
CALL ENGINEER
4.
Key in 7890 + Enter.
The display shows:
Ver 4.20
14 FEB 1991
Followed by:
Do you want
engineer reset?
Note: Whenever you enter engineer mode, the software version number and its date
will be displayed. Make a note of this number, as it will be useful when contact-
ing the Scantronic Product Support Department with any queries.
5.
Press No.
The display shows:
Do you want
test functions?
6.
Press No.
The display shows:
Do you want
reports?
7.
Press No.
The display shows:
Do you want to
program the system?
8.
Open the control panel lid.