background image

Operation instructions 

CLOCK button

How to adjust the real time?

1 . Press (cLocK) button.

Result: 

The time flashes on the LCD. 

2. Press<A>and(:f) buttons.

Result: 

Once to increase or decrease the time setting by 1 minute. 

One and a half seconds to increase or decrease the time setting 

by 10 minute. 

For a longer time to increase or decrease the time  by 1 hour. 

3. Press (cLocK) button again.

Result: 

The real time is set. 

SUPER mode

SUPER 

mode is used to start or stop fast cooling or heating. 

SUPER 

mode can  be set when the appliance is in operation or energized. 

In SUPER mode, you can set airflow direction or timer 

How to set SUPER mode?

Press 

s

!

button  at  the  cool  mode. 

Result: 

At high fan speed ,the set temperature 
automatically to 16

°

C. 

Press 

s

!

button  at  the  heat  mode. 

Result: 

At auto fan speed ,the set temperature 
automatically to 30

°

C. 

How to cancel SUPER mode?

¢ 

¢ 

Press  SUPER , MODE, 

FAN, 

ON/OFF,SLEEP or TEMPERATURE SETTING button.

Result: 

Note: 

The display return to the original mode. 

Escape from SUPER mode. 

SMART button is not available in SUPER  mode. 

The Appliance  will continue working in SUPER mode for 15 minutes, if you don't escape from it 

by pressing any of the buttons mentioned above. 

28tl 

12:00 

• 

28tl 

8:30 

• 

0:25 

• 

0:25 

• 

18:30 

INNOVAIR DC INVERTER QUANTUM

REMOTE CONTROL MANUAL

6

Summary of Contents for WIN310C2V31

Page 1: ...QUANTUM INVERTER MINI SPLIT REMOTE CONTROL USERMANUAL WIN310C2V31 WIN414C2V31 WIN520C2V31 WIN628C2V31 ...

Page 2: ...tions 1 Operation modes 3 Airflow direction control 4 Smart mode 5 Clock button 6 Super mode 6 Timer mode 7 Quiet mode 7 Economy mode 8 lfeel mode 8 Dimmer button 8 Sleep mode g INNOVAIR DC INVERTER QUANTUM REMOTE CONTROL MANUAL Contents ...

Page 3: ... set the current time QUIET UsedtosetorcancelQuietModeoperation In this mode the air conditioner will work with low noise performance by low compressor frequency and low fan speed 9 8 10 11 12 13 14 15 16 DIMMER This button will turn off all the displays of indoor unit Press any button to resume displays TEMP Used to adjust the room temperature timer and clock MODE Press this button to select the ...

Page 4: ... air conditioner aim the remote controller to the signal receptor The remote controller will operate the air conditioner at a distance of up to 7m whenpointing at signal receptor of indoor unit CAUTIONS For appropriate signal transmission between remote controller and indoor unit keep the signal receiver away from the following items Direct sunlight or other strong lights or heat Flat panel televi...

Page 5: ...re setting by 1 c HEATING COOLING DRY FAN ONLY 16 C 30 C 7 7 unable to set ff 12 0D Note Heating mode is NOT available for cooling only models Note At Dry mode a decrease or rise of up to re can be set with Remote controller if you still feel uncomfortable Turning on Press button Result The RUN indicator of the indoor unit lights up SWING SMART TIMER ON TIMER OFF CLOCK SLEEP and SUPER operation mo...

Page 6: ... 11 11 button again Result The louvers swing to a suitable angle as desired 1 Horizontal airflow control with the remote controller 1 Using remote controller to set various angles of flow or specific angle as you like Press 1 1 1 1 button once Result The horizontal adjustment louver will swing left and right automatically 1 Press 11 11 button again Result The louvers swing to a suitable angle as d...

Page 7: ...inutes 26 C Target temperature Room temperature decrease 2 c after operate for 3 minutes 26 C Note Temperature airflow and direction are controlled automatically in SMART mode However for the inverter you can choose from 7 to 7 if you still feel uncomfortable What you can do in SMART mode Your feeling Button Adjust Uncomfortable because 8 Indoor fan speed alternates among High Medium of unsuitable...

Page 8: ... or energized In SUPER mode you can set airflow direction or timer How to set SUPER mode Press s R button at the cool mode Result At high fan speed the set temperature automatically to 16 C Press s R button at the heat mode Result At auto fan speed the set temperature automatically to 30 C How to cancel SUPER mode Press SUPER MODE FAN ON OFF SLEEP or TEMPERATURE SETTING button Result Note The disp...

Page 9: ...s the TIMER ON button and confirm it Result A beep can be heard ON stops flashing The TIMER indicator on the indoor unit lights up 4 After the set timer displayed for 5 seconds the clock will be displayed on the LCD of the remote controller instead of set timer How to cancel TIMER ON Press the riMERoN button again Result A beep can be heard and the indicator disappears the time on mode has been ca...

Page 10: ...function will be started Advice to put the remote controller in the place where the indoor unit receive signal easily Advice to cancel the FEEL mode so as to save energy when stopping the air conditioner How to cancel FEEL mode Q 0 button once again Press the Result The transmit signal in the display will disappear and the IFEEL function will be shut off Note If the FEEL function can t be shut off...

Page 11: ...se by 1 C after 6 hours then decrease by 1 C after 7 hours Set temperature will decrease by 2 C if the appliance operates in heating mode for 2 hours constantly rise by 1 C after 6 hours then rise by 1 C after 7 hours SLEEP mode 3 Set temperature will rise by 1 C if the appliance operates in cooling mode for 1 hour rise by 2 C after 2 hours then decrease by 2 c after 6 hours decrease by 1 c after ...

Reviews: