INSTALLATION   INSTRUCTIONS

1. For the left-hand and right-hand  piping,

remove the pipe cover from the side panel.

2. For the rear-right-hand and rear-left-hand

piping, install the piping as shown in Fig.10.

    

3. Fix the end of the connective pipe. (Refer 
    to Tightening Connection in REFRIGERANT 
    PIPING CONNECTION)

Connective pipe installation

2. When connecting extension drain hose,

insulate the connecting part of extension
drain hose with a shield pipe, do not let
the drain hose slack.

Right-hand piping

Left-hand piping

Rear-right piping

Rear-left piping

Fig.8

Fig.9

Fig.10

4. Piping and wrapping

Bundle the tubing, connecting cable, and drain 
hose with tape securely,  evenly as shown in Fig.11.
   Because the condensed water from rear of the 
   indoor unit is gathered in ponding  box and is 
   piped out of room. Do not put anything else in 
   the box.

Indoor unit

Connective
pipe

Pipe room

Ponding box

Wrapping belt

Connective
cable

Drain hose

Fig.11

Connect the indoor unit first, then the 
outdoor unit. 
Do not allow the piping to let out from 
the back of the indoor unit.
Be careful not to let the drain hose slack.
Heat insulated both of the auxiliary piping. 
Be sure that the drain hose is located at 
the lowest side of the bundle. Locating 
at  the upper side can cause drain pan 
to overflow inside the unit.
Never intercross nor intertwist the power 
wire with any other wiring.
Run the drain hose sloped downward to 
drain out the condensed water smoothly.

CAUTION

3. Connective Pipe and Drainage

Installation

1. Run the drain hose sloping downward. Do

not install the drain hose as illustrated in
Fig.7.

Drainage

Fig.7

Do not block water flow by a rise.

Do not put the end of 
drain hose into water.

Wall

Indoor

Outdoor

5-7mm

Fig.6

2. Drill a hole in the wall

  

1. Determine hole positions according to the
    diagramdetailed in Fig.5. Drill  one (1) hole 
    (

65mm) slanting slightly to outdoor side.

2. Always use wall hole conduit when

drilling metal grid, metal plate or the like.

Summary of Contents for VWM0810H21

Page 1: ...Installation Manual DC INVERTER MULTI TYPE VWM0810H21 VWM1013H21 VWM1320H21 INDOOR DC INVERTER MULTI SERIES ...

Page 2: ...he specified cable and connect tightly and clamp the cable so that no external force will be acted on the terminal If connection or fixing is not perfect it will cause heat up or fire at the connection 7 Wiring routing must be properly arranged so that control board cover is fixed properly If control board cover is not fixed perfectly it will cause heat up at connection point of terminal fire or e...

Page 3: ...or rain exposure make sure that heat radiation from the condenser is not restricted Ensure that the clearance around the back of the unit is more than 30cm and left side is more than 30cm The front of the unit should have more than 200cm of clearance and the connection side right side should have more than 60cm of clearance Do not place animals and plants in the path of the air inlet or outlet Tak...

Page 4: ...h it on the connective cable between indoor unit and outdoor unit after installation Cord protection rubber ring If the cord clamp can not fasten the cord for the small size of the cord please use the cord protection rubber ring supplied with accessories to wrap on the cord then fix it with the cord clamp Transfer connector NOTE Pipe size differ from appliance to appliance To meet different pipe s...

Page 5: ...ise Two of the A B and C directions should be free from obstructions CAUTION INSTALLATION INSTRUCTIONS 5 CAUTIONS One Two One Three One Four One Five More than 12cm More than 12cm Air filter Air filter Remote controller Remote controller More than 12cm Air filter Remote controller Remote controller Air filter More than 12cm More than 15cm More than 12cm Air filter Remote controller More than 10cm ...

Page 6: ...xample Dimensions are in mm unless otherwise stated 150mm or more to ceiling Indoor unit outline Installation plate H Right rear side refrigerant pipe hole 65 Left rear side refrigerant pipe hole 65 120mm or more to wall 120mm or more to wall W 45 R L 45 W W 45 H H Right rear side refrigerant pipe hole 65 Installation plate Indoor unit outline Left rear side refrigerant pipe hole 65 150mm or more ...

Page 7: ...onding box Wrapping belt Connective cable Drain hose Fig 11 Connect the indoor unit first the n the outdoor unit Do not allow the piping to let out from the back of the indoor un it Be careful not to let the drain hos e slack Heat insulated both of the auxiliary piping Be sure that the drain hos e is located at the lowest side of the bun dle Locating at the upper side can cau se drain pan to overf...

Page 8: ...between the indoor unit and the wall Get it out after finish piping 4 Push the lower part of the indoor unit up on the wall then move the indoor unit from side to side up and down to check if it is hooked securely 4 Indoor unit installation Max Length for all rooms OU higher than IU 1 drive 2 30m 45m 60m 75m 20m 25m 30m 30m 10m 10m 10m 10m 15m 15m 15m 15m 10m 10m 10m 10m 1 drive 3 1 drive 4 1 driv...

Reviews: