SAFETY PRECAUTIONS

WARNING

      Read the follow SAFETY PRECAUTIONS carefully before installation.
      Electrical work must be installed by a licensed electrician. Be sure to use the correct rating 
      of the power plug and  main circuit for the model to be installed.
      Incorrect installation due to ignoring of the instruction will cause harm or damage. 
          

The seriousness is classified by the following indications.

This symbol indicates the possibility of death or serious injury.

The items to be followed are classified by the symbols:

Symbol with background white denotes item that is PROHIBITED from doing.

CAUTION

This symbol indicates the possibility of injury or damage to property.

WARNING

1) Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water

leakage, electrical shock or fire.

2) Install according to this installation instructions strictly. If installation is defective, it will cause water

leakage, electrical shock or fire.

3) Use the attached accessories parts and specified parts for installation. otherwise, it will cause the set to fall,

water  leakage, electrical shock or fire.

4) Install at a strong and firm location which is able to withstand the set s weight. If the strength is not enough

or installation is not properly done, the set will drop and cause injury.

,

5) For electrical work, follow the local national wiring standard, regulation and this installation instructions. An

independent circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found
in electrical work, it will cause electrical shock or fire.

6) Use the specified cable and connect tightly and clamp the cable so that no external force will be acted on

the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.

7) Wiring routing must be properly arranged so that control board cover is fixed properly. If control board cover

is not fixed perfectly, it will cause heat-up at connection point of terminal, fire or electrical shock.

8) When carrying out piping connection, take care not to let air substances other than the specified

refrigerant go into refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure
in the refrigeration cycle, explosion and injury.

9) Do not modify the length of the power supply cord or use of extension cord, and do not share the

single outlet with other electrical appliances. Otherwise, it will cause fire or electrical shock.

CAUTION

1) This equipment must be earthed and installed with earth leakage current breaker. It may cause electrical

shock if grounding is not perfect.

2) Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and

accumulates at surrounding of the unit, it may cause fire.

3) Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water

may enter the room and damage the furniture.

5)

Do not operate your air conditioner in a wet room such as a bathroom or laundry room.

6)

An all-pole disconnection device which has at least 3mm clearances in all poles , and have a

leakage current that may exceed 10mA, the residual current device (RCD) having a rated residual
operating current not exceeding 30mA, and disconnection must be incorporated in the fixed wiring
in accordance with the wiring rules.

4)

The appliance shall be installed in accordance with national wiring regulations.

Summary of Contents for VWM0810H21

Page 1: ...Installation Manual DC INVERTER MULTI TYPE VWM0810H21 VWM1013H21 VWM1320H21 INDOOR DC INVERTER MULTI SERIES ...

Page 2: ...he specified cable and connect tightly and clamp the cable so that no external force will be acted on the terminal If connection or fixing is not perfect it will cause heat up or fire at the connection 7 Wiring routing must be properly arranged so that control board cover is fixed properly If control board cover is not fixed perfectly it will cause heat up at connection point of terminal fire or e...

Page 3: ...or rain exposure make sure that heat radiation from the condenser is not restricted Ensure that the clearance around the back of the unit is more than 30cm and left side is more than 30cm The front of the unit should have more than 200cm of clearance and the connection side right side should have more than 60cm of clearance Do not place animals and plants in the path of the air inlet or outlet Tak...

Page 4: ...h it on the connective cable between indoor unit and outdoor unit after installation Cord protection rubber ring If the cord clamp can not fasten the cord for the small size of the cord please use the cord protection rubber ring supplied with accessories to wrap on the cord then fix it with the cord clamp Transfer connector NOTE Pipe size differ from appliance to appliance To meet different pipe s...

Page 5: ...ise Two of the A B and C directions should be free from obstructions CAUTION INSTALLATION INSTRUCTIONS 5 CAUTIONS One Two One Three One Four One Five More than 12cm More than 12cm Air filter Air filter Remote controller Remote controller More than 12cm Air filter Remote controller Remote controller Air filter More than 12cm More than 15cm More than 12cm Air filter Remote controller More than 10cm ...

Page 6: ...xample Dimensions are in mm unless otherwise stated 150mm or more to ceiling Indoor unit outline Installation plate H Right rear side refrigerant pipe hole 65 Left rear side refrigerant pipe hole 65 120mm or more to wall 120mm or more to wall W 45 R L 45 W W 45 H H Right rear side refrigerant pipe hole 65 Installation plate Indoor unit outline Left rear side refrigerant pipe hole 65 150mm or more ...

Page 7: ...onding box Wrapping belt Connective cable Drain hose Fig 11 Connect the indoor unit first the n the outdoor unit Do not allow the piping to let out from the back of the indoor un it Be careful not to let the drain hos e slack Heat insulated both of the auxiliary piping Be sure that the drain hos e is located at the lowest side of the bun dle Locating at the upper side can cau se drain pan to overf...

Page 8: ...between the indoor unit and the wall Get it out after finish piping 4 Push the lower part of the indoor unit up on the wall then move the indoor unit from side to side up and down to check if it is hooked securely 4 Indoor unit installation Max Length for all rooms OU higher than IU 1 drive 2 30m 45m 60m 75m 20m 25m 30m 30m 10m 10m 10m 10m 15m 15m 15m 15m 10m 10m 10m 10m 1 drive 3 1 drive 4 1 driv...

Reviews: