SERVICE MANUAL
Innovair Elite Mini Split
2
5
1. Under heating mode: auto speed under heating or auto heating mode:
a. When T
amb.
≤T
preset
+1°C(1.8°F
), indoor fan will operate at high speed;
b. When T
preset
+1°C(1.8°F)<T
amb.
<T
preset
+3°C(5.4°F
), indoor fan will operate at medium speed;
c. When T
amb.
≥T
preset
+3°C(5.4°F
), indoor fan will operate at low speed;
There should be at least 180s operation time during switchover of each speed.
2. Under cooling mode: auto speed under cooling or auto cooling mode:
a. When T
amb.
≥T
preset
+2°C(3.6°F
), indoor fan will operate at high speed;
b. When T
preset
<T
amb.
<T
preset
+2°C(3.6°F
), indoor fan will operate at medium speed;
c. When T
amb.
≤T
preset
, indoor fan will operate at low speed
There should be at least 210s operation time during switchover of each speed.
(7) Buzzer Control
The buzzer will send a “Di” sound when the air conditioner is powered up or received the information sent by the remote control or there is
a button input, the single tube cooler doesn’t receive the remote control ON signal under the mode of heating mode.
(8) Auto button
If the controller is on, it will stop by pressing the button, and if the controller is off, it will be automatic running state by pressing the button,
swing on and light on, and the main unit will run based on the remote control if there is remote control order.
(9) Up-and-Down Swinging Control
After starting the machine, if you don’t set the swinging functi on,
will move to D clockwise; under other modes, the up-and-down air
the machine, then the wind blade will swing between
L
and D. The air
Location D, Location L to Location D, stop at any location between L-D (the included angle between L~D is the same).
fectual only on condition that setting the swinging order and the inner
(10) Left&Right swing control(only for the mode with this function)
①
has not been set after start-up of the unit, vertical louver will turn clockwise to position D in heating mode, or turn clockwise to position L
in
other modes.
②
If swing function is set when turning on the unit, the vertical louver will swing between L
and D.
Vertical louver has 7 swing statuses:
◆
Stay at position L: control by remote controller:
◆
Stay at position A: control by remote controller:
◆
Stay at position B: control by remote controller:
◆
Stay at position C: control by remote controller:
◆
Stay at position D: control by remote controller:
◆
Swing between
L
and D: control by remote controller:
,
,
,
◆
Stop at any position between
L
and D (angles between
L and D are equiangular), control by remote controller: OFF
③
When turning off the unit, vertical louver will close at position O.
④
Swing action is valid only when swing command has been set and the IDU fan motor is operating.
(
11) Display
①
Operation pattern and mode pattern display
All the display patterns will display for a time when the power on, the operation indication pattern will display in red under standby status.
When the machine is start by remote control, the indication pattern will light and display the current operation mode (the mode light in
-
cludes: Cooling, heating and dehumidify). If you close the light key
, all the display patterns will close.
②
Double-8 display
According to the dif
ferent setting of remote control, the nixie light may display the current temperature (the temperature scope is from 16°C
(60.8°F
)
to 30°C
(86
°F
)) and indoor ambient temperature.
The set temperature displayed in auto cooling and fan mode is 25°C(77°F
) and
the set temperature displayed in auto heat
ing mode is 20°C
(68
°F
). Under heating mode, nixie tube
displays H1 or heating indicator is o
ff
0.5
s
and blinks 10s in defrosting.(If you set the fahrenheit temperature displa
y, the nixie light will display according to fahrenheit temperature)(
11
)
Protection function and failure display
F1: Indoor ambient sensor start and short circuit (continuously measured failure in 5s)
H
eating angle
O(0°
)
L
A
B
C
D
C
ooling angle
O(0°
)
L1
A1
B1
C1
D1
F2: Indoor evaporator sensor start and short circuit (continuously measured failure in 5s)
F3: Outdoor ambient sensor start and short circuit (continuously measured failure in 30s)
F4: Outdoor condenser sensor start and short circuit (continuously measured failure in 30s, and don’t measure within 10 minutes after
defrosted)
F5: Outdoor exhausting sensor start and short circuit (continuously measured failure in 30s after the compressor operated 3 minutes)
H5: Module protection PH: High-voltage protection PL: Low-voltage protection
H3: Overload protection of compressor
P1: Nominal cooling and heating test
P3: Medium cooling and heating test
P2: Maximum cooling and heating test
P0: Minimum cooling and heating test