background image

MU8002-012ENEU rev03

INSTRUCTION AND SAFETY MANUAL XTIRPA™ 

1067mm (42») PORTABLE MANHOLE GUARD 

SYSTEM FOR PPE

UNIVERSAL RESCUE SYSTEM 

IN-8002

INNOVA Public Utility Products Inc. 
1040 Boulevard Industriel, Granby, Québec, Canada 
Tel (450) 777-1240 Fax (450) 372-9936 www.xtirpa.com

TO BE READ AND UNDERSTOOD BY USER PRIOR TO EACH USE

Summary of Contents for XTIRPA IN-8002

Page 1: ...67mm 42 PORTABLE MANHOLE GUARD SYSTEM FOR PPE UNIVERSAL RESCUE SYSTEM IN 8002 INNOVA Public Utility Products Inc 1040 Boulevard Industriel Granby Qu bec Canada Tel 450 777 1240 Fax 450 372 9936 www xt...

Page 2: ...EPI is in conformity with the provisions of the regulation EU 2016 425 and complies to the standard Personal fall Protection Equipment type B EN 795 2012 is identical to the PPE product which was subm...

Page 3: ...MPORTANT The buyer must complete and return the limited warranty registration form Always keep this Instruction and safety manual available to any worker needing to use the XTIRPA system Before each u...

Page 4: ...certification control phase DESCRIPTION INTERPRETATION OF MARKING SYMBOLS This symbol is used to alert the user to a potential hazard The safety of the worker is in jeopardy It is imperative to follow...

Page 5: ...ards may include but are not limited to high heat fire flame smoke fumes caustic chemicals corrosive environments high voltage power lines sudden changes of pressure explosive or toxic gases or substa...

Page 6: ...s and peo ple which must be qualified and trained on the XTIRPA system and who must have read and understood this Instruction and safety manual before using the XTIRPA system available to do the job j...

Page 7: ...e put in place in order to account for all likely emergencies that could occur while working WARNING Any modification or addition to the equipment cannot be done without the prior written consent of t...

Page 8: ...ommended by the Manufacturer WARNING This system should never be used to transport persons and material at the same time b Substitutions or replacements made with non approved adapters anchors connect...

Page 9: ...ser owner and purchaser of the XTIRPA system waiving all claims rights and recourses against the Manufacturer derived therefrom k Refer to and follow applicable ANSI OSHA CSA CE or other standards and...

Page 10: ...to assure that different equip ment articles are compatible when assembled as system n Life expectancy of the XTIRPA system and its components will be determined based on the conclusions of periodic a...

Page 11: ...r which has been approved by the manu facturer or by the manufacturer itself g If leveling screwing pads do not move freely they must be lubricated with a light machine oil h Establish a monthly inspe...

Page 12: ...aterials including without limitation damages resulting from abuse lack of maintenance improper handling or storage voluntary damages vandalism accidental damages or damages resulting from impact or c...

Page 13: ...RPA system Alterations or misuse of the XTIRPA system or failure to follow instructions may result in serious injury or death for which the Manufacturer disclaims all warranties and liabilities whatso...

Page 14: ...injury or death for which the Manufacturer disclaims all war ranties and liabilities whatsoever the user owner and purchaser of the XTIRPA system waiving all claims rights and recourses against the Ma...

Page 15: ...he manhole guard and lock with the second handle pin C If neces sary install the anti toppling device A2108 18 through the eyelets on each side of the manhole guard and lock with the pin 5 Install the...

Page 16: ...perative to keep the pulling angle at a maximum of twenty two de grees 22 from the lifeline cable or rope as to avoid any frontward load unbalance of the manhole guard and cause it to topple over see...

Page 17: ...has authorized in writing the reuse of the system WARNING For all fall protection devices it is essential for safety purposes that anchor ing device is always positioned correctly and that the task t...

Page 18: ...TIRPA system or of any component or part thereof or failure to follow instructions may result in serious injury or death for which the Manufacturer disclaims all warranties and liabilities whatsoever...

Page 19: ...9 8 CALCULATION DIAGRAM Ground Clearance Pay attention to the distance to the ground Length of the lanyard carabiner Extended length of the absorber Distance between harness buckle and feet 1 5 m Mini...

Page 20: ...CORROSION WELDING OTHER SPECIFY INSPECTED BY CORRECTIVE ACTION TAKEN if required PINS HARDWARE STRUCTURAL DAMAGE TM Any failure to follow the Manufacturer s instructions contained in the Instruction a...

Page 21: ...e Manufacturer s instructions contained in the Instruction and safety manual including with regard to the inspection and maintenance of the XTIRPA system and of components and parts there of will caus...

Page 22: ...MU8002 012ENEU rev03 22 NOTES...

Page 23: ...MU8002 012ENEU rev03 23 NOTES...

Page 24: ...anufacturing Plant Innova Public Utility Productions Inc 1040 Boulevard Industriel Canada Qc Canada J2J 1A4 Phone 450 777 1240 Toll free 1 800 461 1937 www xtirpa com Xtirpa is a registered trademark...