Page 8 of 9
Edition 06/12/2014
INNOTECH
FAS 01-03
INNO
TECH
FAS 01-03
Anchor points on double windows with narrow centre spars must be installed with a
vertical offset (at least 50 mm) (Fig. 6b).
Fig. 6b
Position of the anchor points on the window frame:
(Figs. 7 and 7a)
Creating precise anchor points is necessary for the proper functioning of the fall
prevention system for windows.
We recommend that you use drilling jigs to ensure the
greatest possible precision.
Fig.7
Fig. 7a
•
Select the most suitable and safest points on the window frame to act as anchor
points in the frame seal of the window profile (Fig. 7).
•
Fit only certified INNOTECH guide bushes into all anchor points (Fig. 7).
•
ATTENTION ! ! !
Make sure to drill the anchor points at a right angle on all sides (Fig. 7a).