background image

Page 4 of 9 

Edition 06/12/2014 

INNOTECH 

FAS 01-03

 

FAS 01

 - 1.15 kg

 

FAS 02

 - 1.80 kg 

or  2.50 kg

 

FAS 03

 - 5.30 kg

 

INNO

TECH

   

FAS 01-03

 

 

DESCRIPTION 

 

This fall prevention system for windows consists of a telescopic bar.  This bar can be engaged at 
different adjustment lengths and is fitted with freely protruding anchor pegs on both sides which 
are held in place by anchor bores on the window frame.  This allows restraining persons from 
falling while working at open windows in compliance with all legal regulations.

 

Attaching the telescopic bar requires that you drill horizontal bores into the window frames.  The 
fall prevention system for windows can then be inserted easily and carried along from window to 
window.  Since it can be adjusted to the respective width of the window with only a few steps and 
thanks to the anchor points prepared in the window frame, the telescopic bar safely restrains the 
user and provides reliable protection. 

 
 
 
 

BRIEF INSTRUCTIONS:

 (attention: for exact application, follow pages 5 - 6!) 

 
 
 
 
 
 
 
 
 
 

ADJUSTMENT LENGTHS AND WEIGHT

 (Fig.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

STANDARDS – TEST CRITERIA 

The fall prevention system for windows has been certified to provide collective side protection 
(guardrail) against falls to the outside as required by EN HD 1000/ÖNORM B 4007/ASchG /AAV.  
Test loads according to EN HD 1000 (individual loads of 0.3 kN for elastic deflexions of 

 

 35 mm 

and individual loads of 1.25 kN for plastic deflexions without breaking or coming loose and 
without being shifted from its intended axis by more than 200 mm at each point).  

Summary of Contents for FAS 01

Page 1: ...gestaan nadat de monteur en de gebruiker de originele montage en gebruikershandleiding in de desbetreffende taal gelezen hebben Figyelem MAGYAR A biztonsági berendezés felszerelése és használata csak az után megengedett miután a szerelést végző és a használó személyek a nemzeti nyelvükre lefordított eredeti használati utasítást elolvasták és megértették Pozor SLOVENSKY Montaža in uporaba varnostni...

Page 2: ...fect the safety of the user when working in high places Prior to installation or work consult the responsible authorities as to whether the restraint system is suitable for the intended application Adhere to the respective accident prevention regulations when installing using the attachment device INNOTECH FAS 01 03 Before starting the work you must ensure that no objects can fall to the ground fr...

Page 3: ... fall prevention system Do not put tools or working materials on the fall prevention system Do not use the fall prevention system for windows as a child safety harness Do not use the fall prevention system for windows for hoisting or letting down scaffolds construction materials and cleaning materials etc INNOTECH FAS 01 03 have been developed for personal safety and may not be used for other purp...

Page 4: ...ted easily and carried along from window to window Since it can be adjusted to the respective width of the window with only a few steps and thanks to the anchor points prepared in the window frame the telescopic bar safely restrains the user and provides reliable protection BRIEF INSTRUCTIONS attention for exact application follow pages 5 6 ADJUSTMENT LENGTHS AND WEIGHT Fig 1 STANDARDS TEST CRITER...

Page 5: ...ws with both hands pull locking bolt B and adjust the system to the respective window size using the adapter Correct setting light width of the window frame plus approx 50 mm to 150 mm Fig 3 Attention make sure locking bolt B has snapped back into place after each pre adjustment Proceed by shortening the fall prevention system for windows by pulling locking A pushing the perforated silver extensio...

Page 6: ...and B must be locked securely in place Fig 5 MAINTENANCE All moving parts must be treated with acid free lubricant at least once a year and as needed Check the fall prevention system for windows for obvious defects prior to every use STORAGE Always store the fall prevention system for windows in a dry location and with the spring slackened ATTENTION The FAS 01 03 fall prevention system for windows...

Page 7: ...trength of the window frame and the anchor point A suitable test device PG 01 has been developed by the manufacturer INNOTECH WORK SITE determining the elevation of the anchor point Stand on window sill If the window sill is the highest elevation of the work site install at least 2 telescopic rods at the anchor points marked in red on the window frame Fig 6 Top guardrail always 1 000 mm above the ...

Page 8: ... anchor points is necessary for the proper functioning of the fall prevention system for windows We recommend that you use drilling jigs to ensure the greatest possible precision Fig 7 Fig 7a Select the most suitable and safest points on the window frame to act as anchor points in the frame seal of the window profile Fig 7 Fit only certified INNOTECH guide bushes into all anchor points Fig 7 ATTEN...

Page 9: ... as well as frame and centre spar profiles with hollow cavities or a full cross section Special guide bushes are available from your FAS 01 03 dealer Fig 8 Type FHS GUIDE BUSH TYPE FHB The bushes are installed into the window frame using clips and two screws These bushes are used for instance instead of FHS bushes when the use of FHS bushes is not deemed reasonable or as repair bushes if a bore ha...