Problem: The power cord is plugged in, but the front panel POWER LED is dark.
Solution 1: Make sure that the IN9230 IEC power cable is securely plugged into the unit and the
A/C source.
Solution 2: Make sure the A/C source is live.
Solution 3: The CTL101 contains a 0.25A time delay fuse. To change the fuse, first, disconnect
the power cord. Slide out the fuse holder (located on the rear panel to the left of the IEC cable
receptacle) using the IN9339 alignment tool (included).
Problem: There is no response from the CTL120 Remote and the remote LED on the
front of the CTL101 does not illuminate.
Solution 1: Make sure that the CTL120 is positioned at an angle that is no more that 30 degrees
from the CTL130 IR Sensor.
Solution 2: Make sure that the CTL120 is no farther than 30 feet from the IR Sensor.
Solution 3: Make sure that the IR sensor mode switch is in the correct position.
Solution 4: The batteries in the CTL120 may be old / weak. Replace them if necessary.
For best results, position the emitters and sensors in direct line with each
other whenever possible. The exception to the rule is when the CTL130 IR
emitter is involved in the application. Do not place the CTL101 in a loca-
tion where the unit’s sensor window will detect the emitter signal, or in an
area in which the signal could feed back into the unit. This condition is evi-
dent whenever a remote control command is issued and the remote LED on
the CTL101 remains "ON" even after the remote control button is released.
Problem: While setting up the IR remote control for a new manufacturer / component for
the first time, a "Signal Error" message appears on the screen.
Solution 1: The "Signal Error" may result from the CTL101 adjusting to a new code format. Try
again.
Solution 2: If the "Signal Error" message occurs three times, then the manufacturer / component
is incompatible with the CTL101. Try another manufacturer’s code format on your remote
control.