7
X2 Cap
The new X2 cap has a built in Damper that prevents clatter and noise when the give
adjustment is used.
Note: The Damper makes the machine slightly louder when running without needles or when
the adjustment is set to the hardest setting. When the machine is set up with needles and soft
give setting are used the clatter and noise will be greatly reduced compared to running without
it.
The Damper has a service life of approximately 1500 hours. The machine can be operated
without the Damper if the give adjustment is not required. To remove the Damper from the
cap use a pliers and grab the tip of the Damper to pull it out from the Damper plug.
Don’t
grab the shaft of the Damper as it can be damaged. To insert the Damper use the adjustment
screw as a guide to locate the hole in the Damper plug. Apply pressure to the damper to insert
it firmly.
1.
2.
3.
X2 Cap
Damper plug
Damper