INSTRUCTION MANUAL
REVISION 4.0 • APRIL
2020
Only use the approved ProXcide™ chemicals with the
ProXcide™.
Regularly check that the ProXcide™ (including its cables
and accessories) are free from damage. Do not use the
ProXcide™ if damaged, please contact Inivos for repair.
Do not attempt to open the ProXcide™. There are no user
serviceable parts inside. Opening the ProXcide™ could be
dangerous, and will invalidate the warranty.
Never tilt the ProXcide™ unit more than 30 degrees from
vertical, this can lead to chemical leakage.
Never enter a space where the ProXcide™ is operating
until the deactivation cycle has completed and the solid
green light is showing on the process monitor. A portable
gas sensor must also register a hydrogen peroxide level
below 2ppm for
≤
15 mins re-entry/day, and 1ppm for longer
periods / reoccupation of the room.
ProXcide™ contains
≤
7.5% hydrogen peroxide and can
cause serious skin and eye irritation. Therefore always wear
protective gloves and eye protection whilst inserting or
removing ProXcin™. refills from the ProXcide™ unit. Also read
the MSDS for ProXcin™.
It is recommended that the ProXcide™ be connected to the
mains through an 30mA RCD adaptor.
Never insert or remove a refill from the ProXcide™ unit
unless instructed to do so by the control panel. Failure to
observe this requirement may lead to chemical spillage.
Always carry out a site and location specific risk
assessment, taking into consideration the hazard analysis
and risks reduction identified. Implement suitable control
measures to avoid damage to property, or harm or injury to
any person.
Only trained operatives must use the ProXcide™. Use by
untrained personnel can lead to death or injury.
Section 1:
Essential safety information
Do not operate the ProXcide™ in wet conditions. It is normal
for the outer casing of the unit to become damp after
running a process, but the unit must not be used in wet
conditions .
When the ProXcide™ is operating, all personnel and animals
must remain outside of the treatment space.
You must close and seal all entry and exit points to the room
and all windows, and cover ventilation and smoke detectors,
so that the vapourised hydrogen peroxide is contained to
the area being treated.
Always display appropriate hazard warning and no entry
signs on all doors whilst the ProXcide™ is operating.
Never attempt to use the ProXcide™ for any purpose other
than its intended use as a decontamination system.
Always disconnect the system from the mains supply when
not in use.
The wall socket used for ProXcide™ must be earthed.
Fully read this user manual and complete the user training
provided by Inivos before attempting to operate the
ProXcide™.
Do not use harsh or abrasive chemicals to clean the
ProXcide™ unit or its accessories. A damp cloth only should
be used, with a mild detergent such as washing up liquid, or
mild alcohol wet wipes.
The ProXcide™ must be PAT (Portable Appliance Testing)
tested for electrical safety every six months.
Where the fire alarm cap is used for the decontamination
process, the fire safety o
ff
icer must be informed to mitigate
the risks of fire within the decontamination area for the
duration of the process.
Summary of Contents for ProXcide
Page 8: ...8 www inivos com INSTRUCTION MANUAL REVISION 4 0 APRIL 2020 1 2 ...
Page 41: ...APRIL 2020 REVISION 4 0 INSTRUCTION MANUAL 41 Issue 4 Pop up box for issue 4 ...
Page 42: ...42 www inivos com INSTRUCTION MANUAL REVISION 4 0 APRIL 2020 Issue 5 Pop up box for issue 5 ...
Page 43: ...APRIL 2020 REVISION 4 0 INSTRUCTION MANUAL 43 Issues 12 Pop up box for issue 12 ...
Page 44: ...44 www inivos com INSTRUCTION MANUAL REVISION 4 0 APRIL 2020 Issue 13 Pop up box for issue 13 ...
Page 45: ...APRIL 2020 REVISION 4 0 INSTRUCTION MANUAL 45 Issues 16 to 20 Pop up box for issues 16 20 ...