background image

11

 

 

Inis

 

Meain

 

MK2

  

Roomheater

 

stove

 

 

 

 

 
Installation Instructions

 

presence

 

of

 

asbestos

 

is

 

found

 

please

 

 

The

 

wooden

 

crating

 

the

 

stove

 

was

 

shipped

 

in

 

can

 

be

 

cut

 

up

 

for

 

wood

 

logs

 

in

 

the

 

stove.

 

Health and Safety

 

precautions

 

 

Please

 

ensure

 

that

 

the

 

installation

 

of

 

the

 

stove

 

complies

 

with

 

all

 

the

 

requirements

 

of

 

the

 

relevant

 

Health

 

and

 

safety

 

at

 

work

 

acts

 

applicable.

 

Some

 

materials

 

used

 

in

 

fire

 

cement

 

are

 

caustic

 

and

 

contact

 

with

 

the

 

skin

 

should

 

be

 

avoided.

 

In

 

case

 

of

 

contact

 

with

 

the

 

skin

 

wash

 

with

 

plenty

 

of

 

cold

 

water.

 

If

 

any

 

structural

 

work

 

is

 

required

 

for

 

installation

 

please

 

take

 

note

 

of

 

the

 

possible

 

presence

 

of

 

asbestos.

 

If

 

the

 

contact

 

a

 

registered

 

asbestos

 

removal

 

firm.

 

Proper

 

air

 

supply

 

must

 

be

 

insured

 

to

 

the

 

room

 

into

 

which

 

the

 

stove

 

is

 

to

 

be

 

installed.

 

A

 

permanent

 

vent

 

opening

 

with

 

a minimum free area of 65 cm sq. must be

 

present and ensure that the vent cannot

 

be blocked for example by fallen leaves

 

and that any grills that fit the vent do

 

not lessen the cross section of the

 

vent.

 

Under no circumstances should there be

 

an extractor fan in the same room as the

 

stove, to avoid the possibility of

 

Name

 

Units

 

Inis

 

Meain

 

MK2

 

Fuel

 

used

 

*

 

 

wood

 

logs

 

Max.

 

measurements

 

of

 

wood

 

logs

 

mm

 

500x100x150

 

Efficiency

 

at

 

nominal

 

heat

 

output

 

%

 

75

 

Nominal

 

heat

 

output

 

kW

 

12

 

CO

 

concentration

 

(at

 

13%

 

O₂)

 

%

 

0.3

 

Flue

 

spigot

 

outside

 

diameter

 

mm

 

163

 

Flue

 

spigot

 

inside

 

diameter

 

mm

 

152

 

Minimal

 

chimney

 

draught

 

at

 

nominal

 

heat

 

output

 

Pa

 

10

 

Average

 

flue

 

gas

 

temperature

 

at

 

nominal

 

heat

 

output

 

⁰C

 

340

 

Combustion

 

gas

 

flow

 

g/s

 

                              10

 

Burning

 

time

 

of

 

the

 

fuel

 

load

 

at

 

nominal

 

heat

 

output

 

h

 

(0,7÷1)

 

Fuel

 

consumption

 

kg/h

 

3.6

 

Measurements

 

 

 

Height

 

mm

 

765

 

width

 

mm

 

700

 

depth

 

mm

 

517

 

Weight

 

,

 

no

 

more

 

than

 

kg

 

187

 

*

 

the

 

time

 

it

 

takes

 

for

 

one

 

load

 

of

 

fuel

 

to

 

burn

 

completely

 

depends

 

on

 

the

 

type

 

of

 

fuel

 

,

 

humidity,

 

amount

 

of

 

fuel

 

in

 

one

 

load

 

,

 

and

 

other

 

factors

 

Summary of Contents for Meain MK2

Page 1: ...1 Inis Meain MK2 Roomheater stove EN Inis Meain MK2 12kW Room Heating Stove User and installation manual The instruction satisfies relevant local national and European standards ...

Page 2: ...le using it properly The stove Inis Meain MK2 Room heater confirms to LST EN13240 standard requirements Stove Inis Meain MK2 Room heater confirms to enviornment and manufacturing requirements NOTICE Before installation and operation of the Fireplace Stove please read this manual This will help you to properly install and the most effecively use the product purchased and to avoid accidents When buy...

Page 3: ...not re enter the building until it is deemed safe to do so Please store this document in a safe place with your receipt as a warranty document Stove features As shown in fig 1 the twin doors are opened by Fig 2 turning the right side handle anti clockwise over 90 degrees to just beyond vertical When the right door is opened it pulls the left door opened as well to aid re fuelling the stove and bei...

Page 4: ... to cure the paint is to put on a strong fire before the stove has cooled down at full output for at least one hour The stove paint will emit fumes with are non toxic but a window should be opened to avoid fume build up during the curing process Before you operate the stove consult with the installer that all the relevant work has been carried out correctly and that they have ignited a small fire ...

Page 5: ...lling should only be needed every 45 minutes at full output and the stove will operate most efficiently and cleanly this way Once the stove is fully hot the control knob can be used to adjust the firing rate down to the required output Fill the firebox up but do not have fuel over flowing over the firebar Household waste should never be burned in the stove Never burn petroleum coke in this stove a...

Page 6: ...he stove dampers can then be closed down With the damper almost fully closed and the correct draught in the chimney an 8 12 hour burn time is possible For more heat output over a shorter time span the damper can be opened up as necessary To avoid excessive blackening of the glass the damper should be left slightly open To revive the fire after overnight burning riddle the grate refuel the firebox ...

Page 7: ...7 one at a time by pulling them slightly forward along their length until the retaining lugs are free of their slots The plates can then be lowered away and removed Please see Fig below ...

Page 8: ...he firebox can be cleaned out never clean the stove if it is still hot Inspect all internal parts of the stove and replace if needed Only Inis Stoves genuine parts should be used in the stove To clean the paint of the stove we recommend the use of a slightly damp cloth with a mild detergent Avoid using abrasive material on the paint of the stove If the stove is to be unused for a prolonged period ...

Page 9: ...himney 4 Chimney draught below 10Pa Riddler grate is locked up won t operate 1 A foreign body like a stone or steel nail has jammed the riddler assembly Dis assemble the riddler mechanism and check Glass blackens excessively If the stove is fitted correctly and the correct lighting and operation of the stove is adhered to blackening of the glass should always burn off after a period of full output...

Page 10: ...Firstly contact the installer and discuss the issue with them If further help is needed please contact the retailer of the stove We take pride in choosing retailers who have a proven track record in customer service If we still have an issue that hasn t been resolved please contact the Inis Stoves technical department Please have this manual with you when you call ...

Page 11: ...area of 65 cm sq must be present and ensure that the vent cannot be blocked for example by fallen leaves and that any grills that fit the vent do not lessen the cross section of the vent Under no circumstances should there be an extractor fan in the same room as the stove to avoid the possibility of Name Units Inis Meain MK2 Fuel used wood logs Max measurements of wood logs mm 500x100x150 Efficien...

Page 12: ...d onto the air supply pipe To bring air to this connection duct it is advisable if possible to run a 101 6mm whether proof pipe from one face of the house to the other end which will help to balance high and low pressure zones due to wind conditions The flexible aluminium duct can then be connection to a Tee piece off of the 101 6mm duct The 101 6mm pipe must be fitted with grilles toprevent the e...

Page 13: ...o ensure that a proper draught in the chimney is present A chimney height of atleast 4m from the top of the stove must be used The chimney diameter must be 153mm The chimney must be in good condition be Cleaned and free from cracks and blokages The chimney must not have too great a cross sectional area and if it is Max 200mm Diameter the chimney should be lined with a suitable flue liner for solid...

Page 14: ...ing transport and fitting 2 Check that the chimney is sound and clear 3 The room has vents as described above 4 That all the sealing joints have had time to set properly 5 That all door seals etc are correct and present 6 That the damper is operational and working properly 7 That all installation guidelines have been adhered to 8 That all local national and European guidelines and laws have been f...

Page 15: ...ate 1 10 Handtool 1 34 Riddler barlinkage 1 11 Walnuthandle 2 35 Riddler mechanismouter section 1 12 Doorlockwasher 2 36 Riddler mechanisminner section 1 13 Doorlockspacer 2 37 Firebox side plateleft 1 14 Doorlock 1 38 Firebox side plateright 1 15 Door handlebody 2 39 Fireboxrearsection 1 16 Door lockwear plateclamp 1 40 Vermiculite upperthroatsection 1 17 Doorlockwear plate 1 41 Fluecollar 1 18 D...

Page 16: ...16 Inis Stoves 2010 ...

Reviews: