6
Inis
Meain
MK2
Roomheater
stove
Firing and Refueling
The oven is designed for use with
intermittent, which means that each time
before adding new fuel charge, the former
must be completely burnt,
only the embers must remain in the fireplace.
Before adding a new load , it is necessary to
slightly open the door inoder to even out the
air pressure before the door is opened fully.
This
will prevent the smoke entering into the
room, especially when the chimney draught is
weak. After adding a new load of fuel it is
necessary to close the fireplace door and
fully open the " Easy start" valve. After 1
min "Easy start" is fully closed. Primary air
valve to be held in its
usual position. To get better efficiency of
burning process it is recommended to place
the primary air valve at position 3.
Inorder to warm the surrounding quickly, the
primary air valve must be moved to 4-8. To
prevent from overheating it is not
recommended
to use not more than 3 kg of wood logs in one
loading and it is recommended to place the
woodlogs in the centre of the burning
chamber.
Slow burning
Your
Inis
Meain
MK2
stove
is
capable
of
slow
burning
making
overnight
burning
possible
at
a
reduced
output.
To
achieve
overnight
burning,
open
the
damper
dial
on
the
left
side
of
the
stove
and
“Easy
Start”
dampers
fully
until
the
fire
is
burning
rapidly.
Fill
the
firebox
with
a
full
charge
of
fuel
and
let
it
ignite
fully.
When
the
fire
is
burning
brightly,
the
stove
dampers
can
then
be
closed
down.
With
the
damper
almost
fully
closed
and
the
correct
draught
in
the
chimney,
an
8-12
hour
burn
time
is
possible.
For
more
heat
output
over
a
shorter
time
span
the
damper
can
be
opened
up
as
necessary.
To
avoid
excessive
blackening
of
the
glass
the
damper
should
be
left
slightly
open.
To
revive
the
fire
after
overnight
burning,
riddle
the
grate,
refuel
the
firebox
with
a
small
amount
of
wood
logs
,open
the
dial
damper
and
“Easy
Start”
Manual
dampers
fully.
Please
be
aware
to
avoid
excessive
condensation
in
the
stove
during
prolonged
slow
combustion
and
open
the
damper
more
if
it
does
occur.
After
a
prolonged
period
of
slow
combustion,
the
stove
should
be
fired
at
a
high
rate
for
at
least
30
minutes
to
help
burn
off
excessive
soot
deposits
in
the
stove
and
the
flue
system.
Ash clearance
The
stove
has
two
ash
pans
designed
for
ease
of
handling.
The
ash
pans
should
be
emptied
before
they
are
over
filled
to
protect
the
grate
from
overheating
when
burning
wood
logs
as
the
ash
is
an
excellent
insulator
and
excess
build-up
of
ash
will
cause
grate
damage.
Stove cleaning and
maintenance
Regular
cleaning
is
essential
for
safe
and
efficient
operation
of
the
stove.
During
the
heating
season
it
is
recommended
to
clean
the
stove
weekly
or
fortnightly.
Inspect
on
a
regular
basis
the
condition
of
the
door
seals
and
if
found
to
be
worn
replace
immediately.
Only
clean
the
stove
when
it
is
fully
cold.
A
pair
of
gloves
should
be
used
when
cleaning
the
stove
and
care
should
be
taken
to
avoid
injury
as
a
number
of
the
stove
components
are
quite
heavy.
The
cast
iron
throat
plates
are
removed
Summary of Contents for Meain MK2