background image

Air2-BS200 | © 2020 Inim Electronics S.r.l.

3

1.  Air2 system description

All anti-intrusion systems INIM can manage the two-way wireless system Air2 characterized by a MHz carrier

frequency 868 MHz.

The system components Air2 are:

 

Air2-BS200/50 transceiver module, 50 terminals

 

Air2-BS200/30 transceiver module, 30 terminals

 

Air2-BS200/10 transceiver module, 10 terminals

 

Air2-KF100 4 button remote-control key

 

Air2-Ergo 4 button remote-control key

 

Air2-Pebble 4 button remote-control key

 

Air2-MC200 magnetic contact with shock and tilt sensor in white or brown

 

Air2-MC300 magnetic contact with two I/O terminals, in white or brown

 

Air2-FD100 smoke detector

 

Air2-Aria/W keypad with graphic display

 

Air2-Hedera outdoor sounder, in white or chrome effect

 

Air2-Smarty/W indoor sounderflasher

 

Air2-DT200T dual technology curtain detector, in white or brown

 

Air2-XIR200W PIR detector, 12 m

 

Air2-XDT200W dual technology curtain detector

 

Air2-UT100 universal transceiver

 

Air2-ODI100W outdoor wireless dual-infrared detector

 

Air2-OTT100W outdoor wireless triple-technology detector

Technical specifications of the system Air2

Operating frequency

range

868.0 - 868.6 MHz

selectable channels

868.1, 868.3, 868.5 MHz

RF output power

25mW e.r.p.

Communication type

Two-way

Modulation

GFSK

Device supervision

from 12 to 250 minutes

/PUF

In order to comply with the EN 50131-1 standards the alarm system supervision time must be below 120 minutes.

Summary of Contents for Air2-BS200

Page 1: ... JS 4 8JSFMFTT USBOTDFJWFS NPEVMF E EN 50131 1 EN 50131 3 EN 50131 5 3 EN 50130 4 EN 50130 5 INCERT CEB T031 OTUBMMBUJPO BOE QSPHSBNNJOH NBOVBM ...

Page 2: ...n of Air2 BS200 8 4 1 Addressing of Air2 BS200 9 4 2 Enrolling a wireless device 10 5 System programming Air2 12 5 1 Programming of Air2 BS200 12 5 2 Transceiver parameters 13 5 3 Programming from Air2 BS200 13 6 General information 15 6 1 About this manual 15 6 2 Manufacturer s details 15 6 3 Notes from the Manufacturer 15 6 4 Simplified EU Declaration of Conformity 15 6 5 Documents for the users...

Page 3: ...white or brown Air2 FD100 smoke detector Air2 Aria W keypad with graphic display Air2 Hedera outdoor sounder in white or chrome effect Air2 Smarty W indoor sounderflasher Air2 DT200T dual technology curtain detector in white or brown Air2 XIR200W PIR detector 12 m Air2 XDT200W dual technology curtain detector Air2 UT100 universal transceiver Air2 ODI100W outdoor wireless dual infrared detector Air...

Page 4: ...els of intrusion control panels INIM The module simulates a reader at a programmed address ADD which allows you to configure the remote control keys up to 10 expansion boards at addresses ADD ADD 1 ADD 9 capable of managing the ter minals Additionally each Air2 BS200 allows the Inim control panel to manage up to 4 wireless keypads and 4 wire less sounders 4 Installation and programming manual 100 ...

Page 5: ...nfiguration connectors LJ USB micro connector LJ Tampermicroswitch Open cover LJ Tampermicroswitch Dis lodgement LJ Button P1 LJ Button P2 LJ LED DL1 red LJ LED DL2 blue LJ LED DL3 green LJ LED DL4 yellow LJ PRG LED red LJ Antenna connector 0 LJ Backbox 1 LJ Mounting screw location 2 LJ Tamper screw location 3 LJ Cable entry 4 LJ Enclosure screw hole ...

Page 6: ...lashers 4 2 3 Status LED LED DL1 red LED DL2 blue LED DL3 green LED DL4 yel low PRG LED red Signal Off Discontinuous flashing Off Off Off Wireless data reception Off Off Discontinuous flashing Off Off Programming phase in progress from 1 to 5 for SmartLiving only Off Off Off solid blinking Off Parameter Value undergoing pro gramming for SmartLiving only Off Off Continuous flashing Off Off Enrollme...

Page 7: ...wireless network only when one of its terminals is configured as wireless a simulated expansion board cannot share its assigned address with other hardwired FLEX5 expan sion boards 3 1 Wireless terminals A terminal can be considered a Wireless terminal only underthe following conditions it must not be configured as a Double zone D if configured as a Zone it must not be configured as Shock in the d...

Page 8: ...ted in the vicinity of the mounting position can influence the magnetic field and can result in the reduced operating capacity of the device It is possible to view on the keypads orvia the programming and supervision software the strength of the wireless signal on each wireless device Air2 BS200 this data can be used to optimize the installation pro cess PUF A level 3 signal strength it is recomme...

Page 9: ... cover to the base and replace the enclosure screw UUFOUJPO Do not change the setting of the jumpers on the connectors 4 1 Addressing of Air2 BS200 During the enrolling phase the wireless transceiver Air2 BS200 is integrated into the intrusion control panel INIM by simulating a reader with the address programmed via the module itself ADD by means of buttons P1 and P2 on the PCB up to 10 expansion ...

Page 10: ...ted with the wireless devices During normal operating status of Air2 Smarty W pressing and holding the P2 button will allow you to view but not change the transceiveraddress indicated on its LEDs 4 2 Enrolling a wireless device The enrolling procedure allows you to associate a wireless device INIM with the transceiver Air2 BS200 which acts in conjunction with the intrusion control panel This proce...

Page 11: ...aining terminals must be configured as wireless terminals 4 Start the learning phase from the control panel 5 If you are enrolling an output device that is connected to an output terminal of Air2 MC300 it is neces sary to enable the Broadcast RF zone option PUF The Broadcast RF option must be enabled for each terminal of the device Air2 MC300 concerned ...

Page 12: ... of remote control keys you wish to enroll 1SPHSBNNJOH UIF DPOUSPM QBOFM The actual programming process for control panels Inim Electronics offers the following parameters for the management of the wireless system Air2 Instant reset of wire less magnetic contact If this option is enabled reset of the magnetic reed sensor of wireless detectors will be signalled instantly otherwise signalling has a ...

Page 13: ...MHz Channel 002 868 3 MHz Channel 003 868 5 MHz Disable tamper pro tection This option disables the tamper signal of the transceiver Air2 BS200 Disable the Rolling Code This option disables the use of a rolling code algorithm for the transmission of wireless commands via the moduleAir2 BS200 Deactivation can be useful to the installer when the same wireless command device is used on several sys te...

Page 14: ...number of blinks equal to the number of the current channel 3 channels are available Press button P2 to activate the successive channel to the one currently operating on the Air2 BS200 mod ule At this point press the ENROLL button on all the detectors and sounders access the ENROLL menu on the Aria keypad and press buttons F3 and F4 simultaneously on all the remote control keys This will synchroni...

Page 15: ...rsons authorized by the manufacturer to repair or replace the parts of this system have authorization to work only on devices marketed underthe brand Inim Electronics 6 3 Notes from the Manufacturer The devices Air2 are certified by IMQ Sistemi di sicurezza Italian certification body The information relating to the power supply batteries required by the devices Air2 are provided in the fol lowing ...

Page 16: ...titled to convey for disposal small electronic waste products with dimensions of less than 25cm to the premises of electronic retail outlets with sales areas of at least 400m2 free of charge and without any obligation to buy Appropriate differentiated waste collection for the subsequent recycling of the discarded equipment its treatment and its environmentally compatible disposal helps to avoid po...

Page 17: ...Air2 BS200 2020 Inim Electronics S r l 17 6 6 WEEE ...

Page 18: ...6 General information 18 Installation and programming manual 100 DRAFT ...

Page 19: ...Air2 BS200 2020 Inim Electronics S r l 19 6 6 WEEE ...

Page 20: ...info inim biz _ www inim biz Via dei Lavoratori 10 Loc Centobuchi 63076 Monteprandone AP ITALY Tel 39 0735 705007 _ Fax 39 0735 704912 DCMIINE0A2BS2008E 100 20200604 DRAFT ...

Reviews: