INHECO HeatPAC User Manual Download Page 1

 

Doc ID: 900372-002

October 2018

INHECO HeatPAC

HeatPAC
Part No.: 7900046

► User´s Manual

Summary of Contents for HeatPAC

Page 1: ...Doc ID 900372 002 October 2018 INHECO HeatPAC HeatPAC Part No 7900046 User s Manual...

Page 2: ...anual This manual and the information herein have been assembled with due diligence INHECO GmbH does not assume liability for any misprints or cases of damage resulting from misprints in this manual I...

Page 3: ...ardware installation 12 Scope of Supply 12 How to connect device to the MTC STC 12 Labware Use 13 Installation of Adapter Plates 13 Mechanical Integration 17 software installation 18 Daily Usage 18 Sa...

Page 4: ...zards which without precautionary measures can result in serious injury or even death The signal word CAUTION indicates hazards which without precautionary measures can result in minor to moderate inj...

Page 5: ...ss made or set with one device and another measurement made in as similar a way as possible with a second device 1 4 Warranty The warranty period starts on the date of shipment Any damage caused by op...

Page 6: ...be easily taken down for cleaning or changed to another configuration within minutes The HeatPAC device is mostly used on robotic platforms and systems in Lab Automation The HeatPAC can be operated wi...

Page 7: ...and products and email them to techhotline inheco com immediately Transportation damages must be reported to INHECO within 7 days of delivery The following components should be included in each shipme...

Page 8: ...INHECO In case the label is missing and you do not know the part number and serial number they can also be read out with the software MTC STC Demo Tool which can be downloaded from our login section...

Page 9: ...F to 89 6 F Sensor type two PT100 Outer dimensions for Length x width x height in mm 128 x 89 x 40 Weight incl cord approx 0 86 kg 1 9 lbs Heating capacity 100 Watt Environmental Conditions Tolerable...

Page 10: ...en used Electrical Shock The HeatPAC must not be used if the device itself or the power cable shows visible signs of damage You can suffer an electric shock and injuries if the HeatPAC is not connecte...

Page 11: ...by INHECO Parts provided by other suppliers can impair the functionality of the device Damages due to the use of non original parts are excluded from INHECO s liability 3 3 Malfunctions In case of a...

Page 12: ...t the power cord of the TEC Control Unit Connect the heating cooling shaking device to the appropriate Slot Module and lock the connector The Heated Lid must be connected to a Black Slot Module Connec...

Page 13: ...re safe positioning as well as easy robotic handling of the plate Visit www inheco com to find the adapter which fits your tube reservoir or plate In case you do not find your disposable on the list o...

Page 14: ...th mounting frame to enclose the PCR Adapter and 4 screws and tighten the four screws at the corner finger tight respectively with 0 25Nm Fig 10 PCR Adapter placed on HeatPAC with mounting frame NOTic...

Page 15: ...dapter plate itself has to be fixed with one screw in the middle NOTice If anotherAdapter or the PCR mounting frame is pre assembled please disassemble this first Fig 11 Unscrew the 4 screws at the co...

Page 16: ...omAdapter do not need a frame they are just fixed with one screw in the hole in the middle of the HeatPAC NOTice If anotherAdapter is pre assembled please disassemble this adapter first Fig 15 Unscrew...

Page 17: ...r M4 screws and holes for positioning pins The mounting surface must be firm and even Drilling schematic for secure mounting of the HeatPAC on a working table is shown in the following figure Fig 18 8...

Page 18: ...sequences More complex control sequences can be performed with the software of your robotic platform provider or if you write your own software based on our Firmware Command Set and DLL For more infor...

Page 19: ...ce integrated in workstation controlled by MTC or STC incl part number and serial number controlled by workstation software or INHECO Software Serial numbers are shown on the device labels of the TEC...

Page 20: ...splays the connected MTC STC as well as connected device Click on the button report error codes An additional window appears in which all error codes are displayed Email a screenshot of this window al...

Page 21: ...of the HeatPAC it is recommended to verify the thermal performance at least once a year Depending on the application shorter verification intervals may be required INHECO recommends to use the INHECO...

Page 22: ...packaging Adhere to required environmental conditions for transportation and storage Technical Data page 9 7 8 Shut Down and Disposal The Device has to be disposed of in accordance with environmental...

Page 23: ...k Slot Module connects CPAC HT 2 TEC HeatPAC Teleshake 95 Thermoshake Heated Lid with MTC STC 2400125 8 3 Thermal Adapter for Temperature Transfer All standard adapter can be downloaded from INHECO we...

Page 24: ...INHECO 24 Doc ID 900372 002 October 2018 9 Appendix...

Reviews: