20.7.5. Digital I/O
In this menu the digital inputs and outputs are configured.
The configuration options for the digital outputs are:
Options
Explanation
NO CONFIGURATION
No configuration.
GENERATOR
Auxiliary generator activation signal.
LOW BAT. VOLTAGE
Storage system voltage below parameter set.
HIGH BAT. VOLTAGE
Storage system voltage above parameter set.
NON-CRITICAL LOADS
Connection / disconnection of non-crit. loads when there is no grid or auxiliary
generator.
NEUTRAL GROUND
Connection / disconnection of inverter neutral ground.
AC GRID CONTACTOR
Opening / closing of an external AC contactor for connecting an inverter to the grid
or auxiliary generator.
BATTERY WAKE-UP
Storage system manager activation signal.
ON/OFF BY COMM.
Manual opening / closing via communications.
The digital input options are:
Options
Explanation
NO CONFIGURATION
No configuration.
START/STOP
Start/Stop the inverter.
AC CONTACTOR
External AC contactor status reading.
20.7.6. Change time/date
Change the current time and date.
20.7.7. Change Modbus node
Change the unit's Modbus node number.
20.7.8. PV grounding
Configure the type of PV grounding used in the installation. The grounding is only possible in units with a
transformer.
20.7.9. Enter password
An installer password must be introduced in order to make changes in the unit’s configuration.
The password is
0332
.
This password is reserved for installers and not end users. Ingeteam accepts no liability for incorrect
use of this password.
20.8. Language
Select the language in which you wish to view the display menus.
20.9. Further options
Emergency charge
Switch on the inverter for a brief period of time to charge the storage system.
Partial data reset
This allows the partial energy meters, partial connection time and number of partial connections to be reset.