9.11 Autotest
In some of the unit configurations there is an additional
AUTOTEST submenu. In these configurations this additional
submenu will appear at the end of the main menu.
Press
OK
on AUTOTEST to access the menu.
Once in the menu, you can carry out tests on the voltage and
frequency protections by varying their limits and checking
that they disconnect correctly.
12:00 12/04/10
MAIN MENU
Start / Stop
Reset partial data
Change inverter number
Autotest
12:00 12/04/10
AUTOTEST
Initiate Autotest
Result
Status: Start
To do this you can access the START AUTOTEST and
RESULT functions can be accessed using the
and
keys. The status of the process is displayed at the bottom of
the screen at the same time.
12:00 12/04/10
AUTOTEST
Test result Vmax
Vmax ; 238 V
Vac ; 236 V
Time: 070 ms
12:00 12/04/10
AUTOTEST
Stop Autotest
Result
Status: Vmax
12:00 12/04/10
AUTOTEST
Result Fmax
Fmax ; 50.02 Hz
Fac ; 49.99 Hz
Time: 060 ms
The statuses through which the AUTOTEST algorithm passes and which are shown at the bottom of the screen are:
Status: Completed
. There is no AUTOTEST in progress.
Status: Start.
An AUTOTEST process is starting.
Status: Vmax
. When it is evaluating the upper limit for voltage protection. This shows the voltage protection
value as the algorithm varies it until disconnection is confirmed.
Status: Reconnection
. Each time a Vmax, Vmin, Fmax or Fmin status is completed, the connection status
appears to indicate that it is starting the next AUTOTEST measurement.
Status: Vmin
. When it is evaluating the lower limit for voltage protection. .
Status: Fmax
. When it is evaluating the upper limit for frequency protection.
Status: Fmin
. When it is evaluating the lower limit for frequency protection.
Status: Completed
. When the AUTOTEST is complete.
The AUTOTEST process can be interrupted at any time by selecting the STOP AUTOTEST option which appears
in place of START AUTOTEST while it is being carried out.
Once an autotest has been completed, the results can
be displayed by selecting RESULT. The results are
accessed by pressing
OK
and you move between the
four available screens of results, such as the screens
shown below as example results screens for Vmax and
Fmax.
Installation Manual
INGECON
®
SUN LITE
AAY2000IKI01
AAY2000IKI01
Rev. _B
Date: March 2011
Page 54
54
La copia, circulación o uso de este documento o de su contenido requiere un permiso por escrito. Su in-
cumplimiento será denunciado por daños y perjuicios. Todos los derechos están reservados, incluyendo
aquellos que resulten de derechos de patentes o registro del diseño.
La correspondencia del contenido del documento con el hardware ha sido comprobada. Sin embargo,
pueden existir discrepancias. No se asume ninguna responsabilidad por la concordancia total. La infor-
mación que contiene este documento es revisada regularmente y es posible que se produzcan cambios
en siguientes ediciones.
El presente documento es susceptible de ser cambiado.
The copy, distribution or use of this document or of its content requires written authorisation. Any
breach thereof will be reported for damages. All rights reserved including those of patent rights or
design registration.
The conformity of the document content with the hardware described has been checked. However,
discrepancies may exist. Liability will not be assumed for total concordance. The information contained
in this document is regularly revised and it is possible that there may be changes in subsequent
editions.Other functions may be available which are not covered by this document.
This document may be changed.
Manual de instalación
INGECON
®
SUN LITE
AAY2000IKH01
AAY2000IKH01
Rev. _B
Fecha: Marzo 2011
Page 2