AAS2000IKI01
33
Installation manual
Ingeteam Power Technology, S.A.
5.4.8. Connection for communication via modem-GSM/GPRS + RS-485
At the request of the installer, inverters may optionally be equipped with hardware for communication via GSM/GPRS
phone. This hardware is made up of an “AAX0001 Com GSM/GPRS + RS-485” board and the antenna for the modem.
The unit is provided with a 211 Ohm ferrite rod. The RS-485 cable coming out of the “AAX0001 Com
GSM/GPRS + RS-485” board must be inserted as close as possible to the board, turning it twice
around the hole at its centre.
The board is provided with a bag (attached with a plastic tie) containing the modem antenna and cable. Connect the
rod cable to the cable’s rod output, and feed it out through the holes on the upper left side of the enclosure. Connect
the end that goes outside to the rod and attach it via its magnet to the unit’s enclosure.
Connect the rod cable to the cable’s rod output, and feed it out through the holes on the upper left side of the enclo-
sure. Connect the end that goes outside to the rod and attach it via its magnet to the unit’s enclosure.
See “AAX2002IKH01 Installation Guide for Communications Devices”.
The modem should be connected to the control board using connectors J11 and J12 on the board.
J12
J11
Control board. Fix to connectors J11 and J12
The control board can be found in the electronics block cabinet, both for units with and without (TL) a transformer.