ColdCube Operation
29
Apart from possible problems identified by the red LED light
of the self diagnosis system, other possible problems are:
Problem
Possible Reason
Action
The ColdCube
works
connected to
the AC but not
connected to
12/24 V dc
(everything off)
DC fuse burn out
Replace fuse
DC cord defective or
not properly
connected on socket
Check and, in
case, replace DC
cord
Main switch
defective
Replace main
switch
Electronic unit
defective
Replace
electronic
The ColdCube
works
connected to
12/24 V dc but
not connected
to the AC
(everything off)
Main switch
defective
Replace main
switch
Electronic unit
defective
Replace
electronic
ColdCube
switch on
(controller
glows) but
compressor
and fan don't
run
Error in controller
programming
Re-set on the
right
programming
parameters
Controller defective
(in case compressor
and fan icon on are
lighted)
Replace
controller
Defective wire
connection
Check or replace
wires
ColdCube is
working but fan
is stopped (see
also self
diagnosis)
Defective wire
connection
Check
Fan defective
Replace fan
Electronic unit
defective
Replace
electronic
Problem
Possible Reason
Action