NOTE: The alarms, when enabled, activate the buzzer and
show a code on the display: “HI” for the high temperature
and “LO” for the low temperature alarm. The following
conditions generate the temperature alarms:
High temperature alarm: the temperature measured by
the virtual control probe is above the threshold set for
parameter “AH”
low temperature alarm: the temperature measured by the
virtual control probe is below the threshold set for
parameter “AL”.
Warnings for the relative thresholds: The temperature alarm
has automatic reset. This means that if the temperature returns
above/below the minimum value needed, the alarm signal is
cancelled automatically. To reset all alarms press
SET
and
DEF
for more than 5 seconds. Pressing
PRG
mutes only the
buzzer.
Energy saving tips
•
Allow hot perishable items to cool down first before you
place it into the ColdCube.
•
Do not open the cooling container more often than
necessary.
•
Defrost the cooling container once a layer of ice forms.
•
Avoid unnecessarily low temperature settings.
Replacement of the ColdCube fuse
1.
Switch off the ColdCube.
2.
Pull off the connection cable.
3.
Pry out the fuse (Figure 2 or Figure 3) with a screwdriver.
4.
Replace the defective fuse with a new fuse that has the
same rating as shown on page 16.
5.
Press the fuse back into the housing.
CAUTION: Danger of electrocution! Disconnect the
connection cable before you replace the ColdCube
fuse. .