2
WARNING LABEL IDENTIFICATION
FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN INJURY.
Always wear eye protection
when operating or perform-
ing maintenance on this
tool.
WARNING
WARNING
Always wear hearing
protection when operating
this tool.
Always turn off the air sup-
ply and disconnect the air
supply hose before install-
ing, removing or adjusting
any accessory on this tool,
or before performing any
maintenance on this tool.
WARNING
Air powered tools can vibrate
in use. Vibration, repetitive
motions or uncomfortable po-
sitions may be harmful to your
hands and arms. Stop using
any tool if discomfort, tingling
feeling or pain occurs. Seek
medical advice before resum-
ing use.
WARNING
Do not carry the tool by
the hose.
WARNING
WARNING
Do not use damaged, frayed
or deteriorated air hoses
and fittings.
WARNING
Keep body stance balanced
and firm. Do not overreach
when operating this tool.
WARNING
Operate at 90 psig (6.2 bar/
620 kPa) Maximum air pressure.
90 psig
(6.2bar/620kPa)
ADJUSTMENTS
TORQUE ADJUSTMENT
To adjust the torque on these Twin Blade Impulse
Wrenches, proceed as follows:
1. Remove the Adjustment Hole Plug.
2. Rotate the Drive Shaft until the Torque Adjustment
Screw is visible in the opening.
3. Using a 1.5 mm hex wrench, rotate the Adjustment
Screw clockwise to increase the torque output and
counterclockwise to decrease the torque output.
Do not rotate the Oil Plug.
Make all final adjustments at the job.
4. Replace the Adjustment Hole Plug.
Summary of Contents for 70P3
Page 13: ...MAINTENANCE SECTION 13 Dwg TPA1560 2...
Page 23: ...23 NOTES...