23
Configuration
Installation Option #1
When
digit 2
is set to a value of “
2
,” the options shown in
can be set to the values in the
right column.
Table 1.
Installation option #1: Digit 2 = 2
Display
screen
(mode and
On/Off)
Digit
Option description
Set digit to...
N/A
1
Factory set to 0
Cannot be changed. Not seen in configuration mode.
2
Installation option #1
2
3
Not available.
Factory set to 0.
4
Enable only when a remote
temperature sensor is used
0: Disabled
1: Enabled
5
Central control
0: Disabled
1: Enabled
6
RPM up
0: Disabled
1: Enabled
N/A
7
Factory set to 1
Cannot be changed. Not seen in configuration mode.
8
Drain pump
0: Disabled
1: Enabled (no delay)
2: Enabled (3-min delay)
(a)
9
Not available.
Factory set to 0.
10
Not available.
Factory set to 0.
D11 D12
11
Not available.
Factory set to 0.
12
Master/Slave is automatically
designated by wired remote
control.
(b)
0: Slave
1: Master
N/A
13
Factory set to 2
Cannot be changed. Not seen in configuration mode.